Pack201 | Operator Interface | Section 4
EN | 48
© Bosch Packaging Technology, Inc.
All rights reserved 2012
PARAMETER
DEFINITION
Melted Film Reject Shifts (prod)
This is number of cycles (packages) from the endseal or finseal to the
reject device�
Melted Film Time Limit
This is the time allowed for a package to remain in the heated endseal
or finseal area before the package will be rejected.
Metering % Of Correction
This is a percentage of the product length that the feeder metering belt
will correct for proper product placement�
Metering Offset
This is a correction that may be added to change the position of the
product on the metering belt�
Metric Units (on/off)
When turned ON all screen parameter values are displayed in metric
units (millimeters)� When turned OFF all values are displayed in inch-
es�
Mfg Splice # To Reject (prod)
This is the desired number of packages to reject when a manufacturers
splice is detected�
Mfg Splice Reject Enable
In the ON position the manufacturers splice reject eye is active� In the
OFF position the reject eye is disabled�
Mfg Splice Reject Shifts (prod)
This is the number of cycles from the manufacturers splice reject eye to
the reject device�
NGNS # To Reject
This is the desired number of packages to reject when a missing prod-
uct gap is detected�
NGNS Reject Shifts
This is the number of cycles from the NGNS reject eye to the reject
device�
No Gap No Seal (NGNS) Enable
In the ON position the No Gap No Seal option is active� In the OFF posi-
tion the option is disabled�
No Gap No Seal (NGNS) Reject (on/off)
In the ON position the NGNS reject eye is active� In the OFF position the
reject eye is disabled�
No Gap Normal Stop Enable
When enabled the NGNS feature will cause the wrapper to go to a nor-
mal stop�
No Head Jam Cycles
This is the number of packages that will pass through the cutting head
before the crimpers start rotating again�
No Head Jam Enable
In the ON position the no jam option is active� In the OFF position the
option is disabled�
No Product No Paper (NPNP) Enable
In the ON position the No Product No Paper option is active� In the OFF
position the option is disabled�
NPNP # of Delays
This is the number of cycles (packages) between the NoProduct No
Paper eye and the former (+ or - 1)�
NPNP Eye Max Missed
This is the maximum number of consecutive missing products the
NPNP/Missing eye can detect before the wrapper is stopped�
NPNP/Missing # To Reject
This is the desired number of packages to reject when a missing prod-
uct is detected�
NPNP/Missing Shifts
This is the number of cycles from the NPNP/missing reject eye to the
reject device�
Number of Cutting Heads
This is the number of sealing crimpers used on the cutting head�