Pack201 | Section 2 | Safety
© Bosch Packaging Technology, Inc.
All rights reserved 2012
EN | 4
2.3.3 Main Disconnect and Lockout
This main disconnect/lockout is on the endseal guard
on the back side of the wrap-
per and is used to disconnect
all power to the wrapper
circuits. If the wrapper con-
trols overload and the main
circuit breaker trips, move
this switch to the O (OFF)
position , open the electri-
cal enclosure door, reset the
breaker, then close the door
and turn back to 1 (ON).
Whenever performing maintenance on the
equipment, lockout power so that the equipment
cannot be cycled. Lockout the power according to
OSHA Standard 1910.147 by placing the switch in
the O (OFF) position and putting a lock through the
hole in the switch as shown.
The Main Electronic Enclosure has a Disconnect/
Lockout located on the Main Power switch and on
each door. If the machine overloads and the main
circuit breaker trips, move the switch to the OFF
position and lock it out before opening the electrical
enclosure door to reset the breaker.
2.3.4 Maintenance Doors and Covers
Doors that require a tool to open are for qualified
maintenance personnel only and for maintenance
purposes only. Do not open a door requiring a tool,
except for qualified personnel entrusted with the ac
-
cess tool.
Lock
For example, the access tool is needed to open the
electronic enclosure door.