5.2
Continuous operation
Personnel:
n
Mechanics
n
Qualified electricians
Protective equip-
ment:
n
Occupational safety clothing, chemical
resistant
n
Safety shoes
n
Safety gloves, chemical-resistant
n
Safety goggles
— Read and follow the safety instructions detailed in
2.12 “Safety instructions for maintenance and rectifying mal-
functions” on page 30
Börger rotary lobe pumps are suitable for continuous opera-
tion.
1.
Make sure that the unit does not become imbalanced due to
inadequate cleaning (adhesive residues of the pumped
medium, threads wrapped around the rotors) or foreign
bodies.
2.
On Börger rotary lobe pumps that operate with a frequency
converter, make sure that the operating speed is sufficiently
below the maximum permissible speed (for speed limit based
on machine configuration, see enclosed data sheet).
3.
Observe the maintenance and inspection intervals according
to
Chapter 6.2 “Maintenance and inspection” on page 114
Operation
BA-Classic FL_en-US, 03.05.2018
www.boerger.de / www.boerger.com
92