18. Flush installation
Screw in the rotating seal holding bush (2) flush with the
gear-side casing protection plate (7) and then unscrew it until
the first groove is aligned with the keyway, see
19. Installation with half undersize
Screw in the rotating seal holding bush (2) flush to the gear-
side casing-protection plate (7) and then unscrew it by half
the undersize (U/2), so that the first grove is aligned with the
keyway, see step 20.
20.
Insert the parallel key (9) so that it fits into the groove of the
rotating seal holding bush (2) and the keyway of the shaft (3).
The side of the parallel key must fit into the rotating seal
holding bush with the nib upwards. If the parallel key consists
of two or three pieces and there is a straight front on one of
the parallel keys, then this must point towards the quick-
release cover.
A.
Flush installation
B. Recessed
C. Protruding
A. Flush installation
B. Recessed
C.
Installation U/2
Maintenance and Repairs