73
Setting the minimum of the cooktop burners
When switching from one type of gas to another, the minimum flow rate
must also be correct: the flame should not go out even when passing
suddenly from maximum to minimum flame. To regulate the flame follow
the instructions below:
Auxiliary, semi-rapid and triple ring:
*
Light the burner.
*
Set the gas valve to the “minimum rate” position.
*
Remove the knob.
*
Using a screwdriver turn the screw “F1” until adjustment is correct (fig. 8.12).
Inside crown of Dual burner:
*
Light the DUAL burner.
*
Set the gas valve to the “minimum rate” position of the inner crown only.
*
Remove the knob.
*
Using a screwdriver turn the screw “F3” until the correct setting is
obtained (fig. 8.13).
Outside crowns of Dual burner:
*
Light the DUAL burner.
*
Set the gas valve to the “minimum rate” position of the inner + outer crowns.
*
Remove the knob.
*
Using a screwdriver turn the screw “F2” until the correct setting is
obtained (fig. 8.13).
For lpg gas, tighten the adjustment screws completely.
EN
Bor
etti Milano / User guide - Installation advice