Profibus DP V1 Agile
55
06/2010
Handling of the Objects
16.5
Actual Value Display of Profibus Data
For analysis purposes,
DP-Master OUT
281 and
DP-Master IN
284 are displayed in the data
transmitted via the Profibus under the actual value parameters.
The parameters are situated in the "Actual values\Actual values frequency inverter" menu of
the VPlus PC-Software.
In these parameters, the data transmitted via the Profibus are displayed in a processed and
comprehensible form. The contents of the process data channel with control word, reference value
etc. are permanently updated. As the communication channel has the contents zero in idling and
transmission is very fast, the contents of the communication channel are stored on the device side
and displayed in the actual value parameters with every transmission.
The displayed content of the communication channel does not correspond to the current state, but the
last transmission.
Handling of the Objects
The following diagrams show the display for a configuration setting with PPO2. The PPO2 includes the
communication PKW channel for parameter access and 6 PZD objects with default settings for In-PZD
objects.
Actual Value
Parameter
DP-Master OUT
281
= C: a nnnn I: iiii 00 V: wwwwww cccc rrrr xxxx xxxx xxxx xxxx
Meaning
C: a
a
= request identification hexadecimal
C: nnnn
nnnn = parameter number
decimal
I: iiii
iiii
= index
hexadecimal
V: ww..w ww..w = parameter value
decimal (with sign in front)
cccc
PZD1 = control word
hexadecimal
rrrr
PZD2 = reference value
hexadecimal, relative to
0x4000 = 100% of the reference value
xxxx
PZD3 user defined
hexadecimal
xxxx
PZD4 user defined
hexadecimal
xxxx
PZD5 user defined
hexadecimal
xxxx
PZD6 user defined
hexadecimal
Actual Value
Parameter
DP-Master IN
284
= C: a nnnn I: iiii 00 V: wwwwww cccc ssss xxxx xxxx xxxx xxxx
Meaning
C: a
a
= reply identification hexadecimal
C: nnnn
nnnn
= parameter number decimal
I: iiii
iiii
= index
hexadecimal
V: ww..w
ww..w = parameter value
decimal (with sign in front)
cccc
PZD1 = state word
hexadecimal
ssss
PZD2 = actual value
hexadecimal, relative to
0x4000 = 100% of the reference value
xxxx
PZD3 = abs. current
hexadecimal, relative to 0x4000 =
100% of the rated motor current
xxxx
PZD4 = active current
hexadecimal, relative to 0x4000 =
100% of the rated motor current
xxxx
PZD5 = Warning
hexadecimal (bit-coded)
xxxx
PZD6 = Fault
hexadecimal