Modbus Agile
02/2011
74
Parameter List
12 Parameter List
The parameter is available in the four data sets.
12.1 Actual Values ("Actual" Menu)
Actual Value Parameters
No.
Description
Units
Value Range
Chapter
RS485/RS232
11
VABus SST-Error-Register
-
0 ... 15
7.3.9
Actual Frequency Inverter Values
249
Active Data Set
-
0 … 4
10
260
Actual Error
-
0 ... 0xFFFF
13.3
270
Warnings
-
0 ... 0xFFFF
13.1
274
Application Warnings
-
0 ... 0xFFFF
13.2
282
Reference Bus Frequency
Hz
-999,99 … 999,99
11
283
Reference Ramp Frequency
Hz
-999,99 … 999,99
11
Bus Control
411
Status Word
-
0 ... 0xFFFF
10
12.2 Parameters ("Para" Menu)
Parameter
No.
Description
Units
Value Range
Chapter
Bus Control
392 state-transition 5
-
Selection
10.4
RS485/RS232
395 Protocol (CM / X21)
-
Selection
5.4
Bus Control
410 Control Word
-
0 … 0xFFFF
10
412 Local/Remote
-
Selection
10
414 Data Set Selection
-
0 … 4
10
Fixed Frequency Values
484 Reference Frequency RAM
Hz
-999,99 … 999,99
10
Fixed Percentage Values
524 Reference Percentage RAM
%
-300,00 ... 300,00
10
Modbus (RTU/ASCII)
1375 Modbus Parity
-
Selection
6
1376 Modbus Address
-
1 … 247
6
1503 Modbus Mode
-
Selection
6
1504 Modbus Baud rate
Baud
Selection
6
1505 Modbus Watchdog Timer
s
0 … 1000
6
Summary of Contents for Agile
Page 1: ...Agile Modbus Communication manual Frequency inverter 230V 400V ...
Page 2: ......
Page 5: ...Modbus Agile 5 02 2011 13 2 Warning Messages Application 76 13 3 Error Messages 76 INDEX 77 ...
Page 44: ...Modbus Agile 02 2011 44 Handling of Data Sets Cyclic Writing ...
Page 69: ...Modbus Agile 69 02 2011 10 2 1 Statemachine diagram ...
Page 78: ......
Page 79: ......