Modbus Agile
21
02/2011
5.4
Set the Protocol for the X21-Connection and Communication Module
395 Protocol (CM / X21)
With Parameter
Protocol (CM / X21)
395, the communication protocol can be selected for an optional
Communication Module (CM) and the X21-Connection.
Protocol (CM/X21)
395
Function
(CM / X21)
0 - CM: VABus / X21: VABus
The slot for an optional Communication Module and the X21-
Connection (RJ45) are set to the VABus communication protocol.
Factory setting.
1 - CM: VABus / X21: Modbus
The slot for an optional Communication Module is set to the VABus
communication protocol. The X21-Connection (RJ45) is set to the
Modbus communication protocol.
2 - CM: Modbus / X21: VABus
The slot for an optional Communication Module is set to the Mod-
bus communication protocol. The X21-Connection (RJ45) is set to
the VABus communication protocol.