32
On-Line
EXPRESS
SYMPTOM
POSSIBLE REMEDY
The modem does
not answer an
incoming call
(contd)
Modem
disconnects
while on-line.
I am having
trouble getting my
init string to work.
Connection
Errors.
I receive a
“Hardware Not
Found Aliased
Addressing” when
I try to load the
DOS driver.
• If you have an answering machine, it may
be answering before the modem can. Turn
the answering machine off, or, use the
software to set auto-answer to respond in
fewer rings than the answering machine.
• Check for any loose connections.
• Re-try the connection by dialing the
number several times. You may be
experiencing line interference.
• An incoming call may have broken the
connection if a call-waiting feature was
enabled. Disable call-waiting and try
again.
• Init strings are primarily personal
preferences. Use the most basic one that
can get the job done. Try: AT&F&C1&D2.
• Try connecting at a lower speed (e.g.,
14.4Kbps, 9600bps).
• Noisy/poor line conditions may prohibit
connection. Have your phone company
test your lines.
• Verify that the modem at the other end is
up to date and compliant with current
CCITT and Bell standards.
• Ensure that jumpers are set correctly on
the modem.