G-15
Off:
Sets the number of pulses to skip each during off
cycle when in the Duty Cycle mode.
Cycles:
Sets the number o DC Increment Cycles to generate
before completion.
To:
Sets the T
0
period which determines the fundamental
output frequency of the unit.
Advanced Channel Menu Increment Extension (FUNC + channel key)
Channel Enable
Increment Wid *
Increment Dly *
Setting the Channel Increment Parameters
To define a pulse requires two parameters: the delay to the active edge and the
width of the pulse.
IncW:
Sets the channel pulse width.
IncD:
Sets the channel delay until the active edge.
Increment SCPI Command Summary
Keyword
Parameter
Comments
:PULSe[0]
Subsystem. Contains commands to control the
output pulse generation. Commands without
suffix refer to the currently selected logical
instrument. See INSTrument subsystem.
:MODe
BINCRement /
Sets the T
0
mode. Added parameters for Burst
Increment and Duty Cycle Increment mode.
:CYCLe
<numeric value>
Sets the number of cycles to generate in Duty
Cycle Increment mode.
:IRESet
1
Resets the width and delay increment
parameters on all channels.
:PULSe[1/2/n]
Subsystem. Contains commands to control the
output pulse generation. Valid suffix range
depends on the number of channels (ChA-1,
ChB-2, etc . . .). Command without suffix refers
to the currently selected logical instrument. See
INSTrument
’s subsystem.
:IWIDth
<numeric value>
Sets the pulse width increment step size.
:lDELay
<numeric value>
Sets the delay increment step size.
Increment Initialization and Reset (FUNC + CLR)
Pressing the
FUNC
key then
CLR
initializes the increment parameters and resets
the delays and pulse widths to their initial conditions. This must be done after
setting all the step parameters, but before generating any pulses.
Increment Specifications
Width Step Size
-1.00 s to 1.00 s
Width Minimum Step
10 ns (-10 ns)