26
WATER PUMPS
The ASDisplay can be used to operate water pumps connected to the ASPower.
Water pumps can be activated by pressing the P1 Button and P2 Button on
the ASDisplay.
NOTE
: The P1 Button and P2 Button will not work if the ASPower has
entered ECO Mode.
BATTERY CHEMISTRY
The battery chemistry of the battery connected to the ASPero system should be
set correctly so the correct charging algorithm is used.
NOTE
: The ASPero system is configured by default to charge lithium LiFePO4
batteries.
To set the battery chemistry of the battery connected to the ASPero system:
1.
On the ASDisplay, hold down the Power Button for three seconds to enter
Settings Mode.
The Power Button LED will flash when you have entered Settings Mode.
2.
Press the ECO Mode Button to toggle battery chemistry between AGM
and Lithium. The toggled battery chemistry LED will flash when selected.
NOTE
: If you have a lead-acid VRLA, lead-acid AGM or lead-acid gel battery,
select
AGM
.
3.
Press the Power Button to exit Settings Mode and save your selection.
BATTERY CAPACITY
The battery capacity of the battery connected to the ASPero system should be
set correctly so the correct charging algorithm is used.
When in Settings Mode, the ASDisplay will show the current set battery capacity
with flashing LEDs in the Water Tank Levels and Battery Level sections.
Each flashing LED in the Water Tank Levels section represents 100Ah, and each
flashing LED in the Battery Level section represents 10Ah.
The value from both sections added together shows the total set Battery
Capacity.