![BMPRO ASPero Owner'S Manual Download Page 31](http://html.mh-extra.com/html/bmpro/aspero/aspero_owners-manual_2779807031.webp)
31
None of my loads appear to be powered, and I can’t use my ASDisplay?
All loads, including any battery monitor in use with the ASPower will power
down if the ASPower was put into Storage Mode.
The ASPower will be put into Storage Mode if:
1.
The switch connected to the ASPower Load Isolation input has been
activated. This turns off power to all caravan loads and accessories
connected to the ASPower CAN bus, such as your battery monitor.
Check that the switch has not been activated.
2.
Battery voltage is very low. The ASPower will enter Storage Mode to
conserve remaining battery voltage, which will disable power to all caravan
loads and accessories connected to the ASPower CAN bus.
Connect the ASPower to a power source and begin battery charging.
I had an external shunt connected but I have removed it. Do I need to do
anything else?
You will need to configure the ASPero system to forget the external shunt,
otherwise it will still behave as if one was connected.
To configure the ASPero system to forget an external shunt:
1.
On the ASDisplay, hold down the Power Button for three seconds to enter
Settings Mode.
The Power Button LED will flash when you have entered Settings Mode.
2.
Press and hold both the P1 Button and P2 Button simultaneously for
five seconds. This will cause the ASPero system to forget the external shunt.
3.
Press the Power Button to exit Settings Mode and save.