TERMINAL/LOAD
CURRENT RATING TERMINAL/LOAD
CURRENT RATING
1 Output
15A
8 Output
10A
2 Output
15A
9 Output
10A
3 Pump (1)
10A
10 Output
10A
4 Pump (2)
10A
11 Output
10A
5 Output
10A
12 Output
15A
6 Output
10A
13 Output
10A
7 Output
10A
14 Output
5A
Table 2:
Designated terminal-load outputs for the load terminal block-positive connection
1.
Load Terminal Block – Positive Connection
Positive wire connection point for the caravan’s 12V loads.
Each output is protected by an internal, electronic, auto-recoverable fuse. This
eliminates the need for the user to replace a blown fuse. If an electronic fuse is
activated, the LED Status Indicator on the ASPower will flash a solid red. The
ASPower will power off the faulty load and resume normal operation once the
fault is fixed.
WARNING
The water pumps must be connected to the correct terminal output in order to be
controlled from the ASDisplay.
2.
Load Terminal Block – Common Negative Connection
Negative wire connection point for the caravan’s 12V loads.
3.
Mains Cable
The ASPower is pre-cabled with a permanent mains power supply cord. The AC
mains input is fitted with an Australian 10A plug.