BATTERY CHARGING MANAGEMENT ALGORITHM
The following describes the Battery Charging Management Algorithm used by
the ASPower when charging the caravan battery from a mains power source.
The ASPower will operate as described when the caravan loads are connected
directly to the ASPower and not the caravan battery.
Battery Capacity
Soft Start
Boost + Bulk-Absorption
Float
≤ 100AH
6 Hours
5 Hours
6 Hours
150AH
6 Hours
7.5 Hours
6 Hours
200AH
6 Hours
10 Hours
6 Hours
250AH
6 Hours
12.5 Hours
6 Hours
≥ 300AH
6 Hours
15 Hours
6 Hours
Table 4:
Timeout for each charging mode based on battery capacity
Figure 5:
ASPower Battery Charging Management Algorithm