40
BLUE
LINE VORTEX 8000Q
Automatic
Pump Out
Does the pump draw water?
Yes / No
Is liquid flow irregular?
Yes / No
Yes / No
Repair or replace the
suction line as required.
Does output drop
and pump is noisy?
Check for debris in valves.
Clean as required.
Yes / No
Is suction line
plugged or collapsed?
Is the automatic pump
out switch in the on position.
Determine and repair
cause of blown fuse.
Replace fuse (30 amp).
Is fuse at automatic
pump out blown?
Turn on switch.
Yes / No
Pump is O.K..
Yes / No
Pump is O.K..
Replace the diaphragms(s),
head and manifold
Yes / No
Check oil level and
refill as required.
Is oil milky coming
from the discharge port?