SECTION 3
BLUE
LINE VORTEX 8000Q
29
6. MAINTENANCE
This section of the operator’s manual contains the
service and maintenance information for the
VORTEX 8000Q®
mobile cleaning unit. A
planned preventative maintenance program will
ensure that your
BLUE
LINE
VORTEX 8000Q®
has optimum performance, long operating life, and
a minimum amount of down time.
!
DO NOT attempt to service this unit while it is
running. High speed parts as well as high
temperature components may result in severe
injury, severed limbs, or fatality.
ENGINE
Refer to the owner’s manual for specific
instructions.
1. Check the engine and transmission oil levels
daily. Ensure that the proper oil level is
maintained.
NEVER
overfill. Check transmission
and PTO (power take off) hoses and lines for leaks.
During the first 50 hours of operation, check the
mounting hardware on the PTO and the PTO drive
line to ensure it is securely tightened (see
drive
belts and pulleys
for hub torque specifications).
After 50 hours of use, periodic inspection of the
PTO oil lines and mounting hardware should be
performed. Maintenance of the PTO should be
performed at the same intervals as the
transmission.
Refer to vehicle owner’s manual
for recommended oil types and regular
maintenance schedule.
2. Check the engine antifreeze coolant daily.
Inspect hoses and pipes daily for leaks.
Refer to
owner’s manual if coolant levels are low for
recommended fluids and fluid levels.
NOTE: Additional engine service information
can be obtained from the vehicle owners’
manual. If service or repair is required, contact
an authorized service center.
VACUUM PUMP
NOTE:
Refer to the provided Vacuum Pump
Operation and Service Manual for specific
instructions.
Lubrication: BLUE
LINE recommends that you
use only PNUELUBE synthetic blower lubricant in
the gear ends of the vacuum pump for all operating
temperatures. PNUELUBE is formulated
specifically for positive displacement blower
service to provide maximum blower protection at
any temperature. One filling of PNUELUBE will
last a minimum of twice as long as a premium
mineral oil.
NOTE:
PNUELUBE (Part # 13-017) is the only
oil that BLUELINE puts in the vacuum pump at
the factory. Adding petroleum oil to synthetic oil is
NOT
recommended.
1. Check the oil level
daily
to ensure the proper
level. Too little oil will damage and ruin the
bearings and gears. Too much oil will result in
overheating.
2. A lubrication valve has been provided on the
front of the hose reel, to prevent rust from building
up inside of the vacuum pump. Plug the vacuum
inlets on the inlet panel and pull out the
ENGAGE
PUM
P switch on the control panel. Spray WD-40
Summary of Contents for VORTEX 8000Q
Page 5: ......
Page 14: ...SECTION 2 BLUELINE VORTEX 8000Q 9 ...
Page 17: ...SECTION 2 12 BLUELINE VORTEX 8000Q Water System 2 1 ...
Page 21: ...SECTION 2 16 BLUELINE VORTEX 8000Q ...
Page 33: ...SECTION 3 28 BLUELINE VORTEX 8000Q Figure 1 Figure 2 Mark Mark ...
Page 75: ...SECTION 4 70 BLUELINE VORTEX 8000Q ...
Page 88: ...SECTION 4 82 BLUELINE VORTEX 8000Q 68 037 ASSY HOSE REEL VAC ONLY 68 045 ASSY WATER SOFTENER ...
Page 89: ...SECTION 4 BLUELINE VORTEX 8000Q 83 68 109 ASSY KIT WATER SOFTENER VRTX ...
Page 90: ...84 BLUELINE VORTEX 8000Q SECTION 5 SERVICE BULLETINS 11 SERVICE BULLETINS ...