36
BLUE
LINE VORTEX 8000Q
PTO Will
Not Engage
Repair or replace wiring
from PTO switch to
PTO solenoid as required.
Check voltage out of
switch (12v min.)
Is voltage present?
Yes / No
Yes / No
Empty the waste tank.
Yes / No
Is waste recovery tank full?
Yes / No
Replace float switch.
Check voltage at the waste
tank shutoff switch (12v min.)
Is voltage present?
Replace PTO solenoid.
Repair or replace
as required.
Repair or replace
wiring as required.
Yes / No
Check voltage at the
start button (12v min.)
Is voltage present?
Check voltage at PTO solenoid (12v min.)
Is voltage present?
Yes / No
Replace switch.
Check if the waste tank shutoff switch is
stuck in the up (shutoff) position.
Is the switch stuck?
Summary of Contents for VORTEX 8000Q
Page 5: ......
Page 14: ...SECTION 2 BLUELINE VORTEX 8000Q 9 ...
Page 17: ...SECTION 2 12 BLUELINE VORTEX 8000Q Water System 2 1 ...
Page 21: ...SECTION 2 16 BLUELINE VORTEX 8000Q ...
Page 33: ...SECTION 3 28 BLUELINE VORTEX 8000Q Figure 1 Figure 2 Mark Mark ...
Page 75: ...SECTION 4 70 BLUELINE VORTEX 8000Q ...
Page 88: ...SECTION 4 82 BLUELINE VORTEX 8000Q 68 037 ASSY HOSE REEL VAC ONLY 68 045 ASSY WATER SOFTENER ...
Page 89: ...SECTION 4 BLUELINE VORTEX 8000Q 83 68 109 ASSY KIT WATER SOFTENER VRTX ...
Page 90: ...84 BLUELINE VORTEX 8000Q SECTION 5 SERVICE BULLETINS 11 SERVICE BULLETINS ...