![Blastrac BMS-270LPII Operating Instructions Manual Download Page 14](http://html1.mh-extra.com/html/blastrac/bms-270lpii/bms-270lpii_operating-instructions-manual_2769639014.webp)
Revision B
Revised 5/20/2003 12:33 PM
12
Operating Instructions BMS-270LPII
Safety Precautions
2.5 Maintenance
Mode
Definition:
State or condition of the multiscraper that minimizes the danger of mechanical, electrical,
pneumatic or hydraulic hazards.
Putting the multiscraper into the maintenance mode:
Move the multiscraper to level ground.
Turn off the ignition switch and remove the key.
Set the parking brake and make sure the multiscraper cannot move.
Wait until all drives have stopped completely.
Depress E-Stop button.
Close propane tank valve.
Remove key from ignition switch.
Let the engine, exhaust system and hydraulic components cool down.
Warning: Engine, exhaust system and hydraulic component temperatures could
be in excess of 200
°
F causing severe burns if touched.