54
SERVMANAGERS
4.3.15 I
DENTIFY
ROM
Unfortunately, as with all complex equipment, problems might arise with
your ServManager that require the assistance of technical-support personnel.
One of the things technicians might want to know when they attempt to
diagnose and correct your problem is the revision level of your ServManager’s
ROM. This command causes the ServManager to send the three-character
“
x
.
x
” ROM level to the currently selected CPU; these characters will be echoed
back to the shared monitor if you are at some type of prompt. To issue the
Identify ROM command, press and release the left Control Key, then type [I].
4.4 Using the Front-Panel Display and Keypad
Through the front panel you can do almost everything that can be done from
the keyboard. The front panel is convenient for configuring and viewing all
configuration items.
4.4.1 N
ORMAL
O
PERATION
4.4.1.A The Power-Up Display
Upon power-up, the display immediately shows the revision of the
ServManager firmware. As the ServManager performs its power-up
diagnostics, it displays a diamond for each step it successfully completes, then
shows “OK” once all tests have completed successfully. If there are failures it
will show an error message on display line 2. If you receive an error message,
see
Appendix C
for an explanation of what it means.
REVISION A1.5
OK
Summary of Contents for ServManager SW995A-R2
Page 84: ...NOTES...
Page 85: ...NOTES...