background image

• Low-voltage shutdown (activates at 10.0 volts DC)
• High-input voltage shutdown (activates at above 15.5 volts DC)
MAXX SST™ uses a 12 volt DC power source like those found in motor vehicles, or it can be operated using
multiple battery configurations with commercial battery chargers or solar battery chargers. For most heavy-duty
applications, a multiple battery configuration and the use of deep-cycle batteries is required.
When using multiple batteries, inverters can be operated from one of the vehicle 12 volt batteries, so there’s
always one battery with adequate charge to start an engine.
MAXX SST™ includes a high-surge capability. This is required to start heavy loads, such as motors and other
inductive devices.

WARNING:

To reduce the risk of injury or property damage: If the appliance does not work or stops

working, unexpectly, or even momentarily, turn off the appliance and disconnect from inverter until the cause is
identified and corrected.

PRINCIPLE OF OPERATION

The MAXX SST™ inverter converts 12 volt DC (direct current) from a vehicle battery or other 12 volt DC power
source to standard 120 volt AC (alternating current) household power.

The Power Inverter Output Waveform

The AC output waveform of the Power Inverter is known as “modified sine wave.” It is a waveform that has
characteristics similar to the sine wave shape of utility power. This type of waveform is suitable for most AC
loads, including linear and switching power supplies used in electronic equipment, transformers, and motors.
The modified sine wave produced by the Power Inverter has an RMS (root mean square) voltage of 120 volts,
which is the same as standard household power. Most AC voltmeters (both digital and analog) are sensitive to the
average value of the waveform rather than the RMS value. They are calibrated for RMS voltage under the
assumption that the waveform measured will be a pure sine wave. These meters will not read the RMS voltage of
a modified sine wave correctly. They will read about 20 to 30 volts low when measuring the output of the inverter.
For accurate measurement of the output voltage of this unit, use a true RMS reading voltmeter such as a Fluke
179, Fluke 79 III series, Beckman 4410 or Triplett 4200.

MODIFIED SINE WAVE AND SINE WAVE COMPARISON

Incompatible  Products:
CAUTION:

Certain products contain power supplies or circuits that are not compatible with an

inverter using a modified sine wave output (such as this inverter) and may be damaged by using this
inverter.
If your product requires pure sine wave AC input power to function properly, the instruction manual
for your  product could state this. If in doubt, you should contact your product manufacturer PRIOR
TO USE. 
Some products must be powered from a pure sine wave power source, such as standard household
power, or a "pure sine wave" inverter in order to function properly.

Your product could be damaged  by this inverter if it contains:
1. Transformer type power supplies  
2. Microprocessor controlled power supplies
3. Capacitive coupled power supplies

If an incompatible product is used with this inverter:
• The product might not operate at all, with no indication of failure.  The product fuse might have

opened as a result of trying to use it with the inverter.

• The product exhibits unusual operation (such as, intermittent operation, buzzing, and the like.)

WARNING:

If the product does not operate normally, to reduce the risk of injury or property damage:

• Turn the product off immediately and unplug it from the inverter. 

S

INE WAVE 

MODIFIED 

S

INE WAVE 

5

4

CAUTION: TO AVOID DAMAGE TO THIS INVERTER OR EQUIPMENT YOU INTEND TO USE WITH THIS

INVERTER:

For Temporary Installation, only use the Black & Decker/Vector Cable Set identified in the

“Installation” and “Specifications” sections of this Instruction Manual. Permanent Installation must be
performed by a professional as specified in the “Installation” section of this Instruction Manual.
• Read And Understand This Instruction Manual Before Using This Unit.

SAVE THESE INSTRUCTIONS

THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE MAXX SST

TM

COMPACT POWER INVERTER MODEL VEC049DCB.

WARNING: TO REDUCE THE RISK OF INJURY:

Follow these instructions and those published by battery manufacturer and the manufacturer of any equipment
you intend to use with this unit. Review cautionary markings on these products and on engine.

INTRODUCTION

Thank you for purchasing the 

VEC049DCB MAXX SST

TM

Compact Power Inverter.

Please read this Instruction

Manual carefully before use to ensure optimum performance and to avoid damage to this product.
This Power Inverter is configured with the latest Soft Start Technology (SST) and supplies continuous power and
peak watts in the form of 120 volt AC outlets to run most household or electronic appliances. Before introduction
of SST, high start-up currents from large inductive loads could shut down an inverter. SST improves inverter
operation by: 
• Gradual voltage ramp-up during inverter start-up, eliminating failed cold starts under load.
• Output that momentarily dips in voltage and quickly recovers to allow large motorized loads to start, eliminating

most shutdowns from momentary overloads. 

• Soft Start technology dramatically increases reliability and life of the product.
Added safety features include automatic shutdown and a low battery alarm to prevent damage to your battery.

FEATURES

On the front panel are two LED indicators. The green LED indicates power and proper operation of the inverter;
the red LED indicates inverter shutdown from over-load or over-temperature condition, or abnormal input
voltages. The ON/OFF Switch turns the inverter ON and OFF. The switch can also be used to force reset of inverter
circuits by switching it OFF, then back ON again. This unit also features a port to attach a remote control (sold
separately).
120 volt AC power is supplied through two North American three-prong type outlets. The outlets can
accommodate either two- or three-pin AC plugs.

Controls and Functions

Maxx SST™ Automatic Features

Built-in Automatic Features include: 
• Overload and over-temperature shutdown activated if AC output exceeds rated watts
• AC short-circuit shutdown
• Low voltage audible alarm (sounds at 10.5 volts input)

PORT FOR 

REMOTE CONTROL

(SOLD SEPARATELY)

GREEN POWER LED
INDICATOR

FRONT VIEW DIAGRAM

BACK VIEW DIAGRAM

WATTAGE POWER
METER

ON/OFF
POWER
SWITCH

(2) 120 VOLT AC
OUTLETS

RED FAULT 

LED INDICATOR

HIGH-SPEED
COOLING FAN

NEGATIVE (–)
TERMINAL

GROUNDING
TERMINAL

POSITIVE (+)
TERMINAL

90550750 VEC049DCB GOOD ONE.qxp  6/5/09  1:46 PM  Page 4

Summary of Contents for Marine Battery

Page 1: ...ww BlackandDecker com NewOwner to register your new product PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON If you have a question or experience a problem with your Black Decker purchase go to HTTP WWW BLACKANDDECKER COM INSTANTANSWERS If you can t find the answer or do not have access to the internet call 1 800 544 6986 from 8 a m to 5 p m EST Mon Fri to speak with an agent Please have t...

Page 2: ...avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used without the safety alert symbol indicates potentially hazardous situation which if not avoided may result in proper...

Page 3: ...might have opened as a result of trying to use it with the inverter The product exhibits unusual operation such as intermittent operation buzzing and the like WARNING If the product does not operate normally to reduce the risk of injury or property damage Turn the product off immediately and unplug it from the inverter SINEWAVE MODIFIED SINE WAVE 5 4 CAUTION TO AVOID DAMAGE TO THIS INVERTER OR EQU...

Page 4: ...r in amperes affects runtime These curves are only estimates of operating time dependent upon The condition of the batteries The state of charge on the batteries The amount of other DC appliances drawing current from the batteries Three curves were developed for a battery of 50 Ampere Hours AH capacity and three for multiple batteries in parallel The higher capacity curves are for 120 AH 200 aH an...

Page 5: ...ust not exceed 6 feet in length 3 A 200 Amp ANL Fuse not supplied installed in the proper Fuse Holder not supplied must be connected in line as part of the positive power source input cable as close as possible to the power source connections 4 A 12AWG insulated wire should be connected between the Grounding Terminal on the inverter see Controls and Functions Back View Diagram on page 4 and the gr...

Page 6: ... cycle marine batteries The DC power source may also be two 12 volt batteries connected in parallel On larger applications the power source may be several batteries connected in parallel as shown in the following Permanent Battery Configuration diagram Note For typical heavy duty uses in a Permanent Installation an ANL fuse must be added as close as possible to the power source battery positive te...

Page 7: ...essory not recommended for use with this tool could be hazardous SERVICE INFORMATION All Black Decker Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool service Whether you need technical advice repair or genuine factory replacement parts contact the Black Decker location nearest you To find your local service location refer to the yellow...

Page 8: ...es graves ÉVITER LES ENVIRONNEMENTS DANGEREUX Ne pas utiliser le convertisseur continu alternatif dans un endroit humide ou mouillé Ne pas utiliser le convertisseur continu alternatif sous la pluie TENIR LES ENFANTS À L ÉCART Tous les visiteurs doivent se tenir éloignés de la zone de travail RANGER LES CONVERTISSEURS CONTINU ALTERNATIF INUTILISÉS À L INTÉRIEUR Lorsqu il n est pas utilisé le conver...

Page 9: ... un port destiné à recevoir une télécommande vendue séparément Un courant alternatif de 120 volts est fourni par quatre prises triphasées nord américaines Les prises peuvent recevoir des fiches pour courant alternatif à deux ou trois broches 17 NE PAS UTILISER de convertisseur continu alternatif ou d appareils électriques à proximité de liquides inflammables ou dans une atmosphère gazeuse ou explo...

Page 10: ... du Maxx SST Voici quelques unes des caractéristiques automatiques intégrées Mise hors tension à la suite d une surcharge ou d une surchauffe qui s active si la puissance nominale est dépassée au secteur Mise hors tension avec court circuit sur secteur Avertisseur sonore de faible tension émis à une tension d entrée de 10 5 volts Mise hors tension en présence de faible tension s active à 10 0 volt...

Page 11: ...e Par exemple une cafetière domestique ordinaire consomme 500 watts pendant l infusion environ 5 minutes mais il ne faut qu environ 100 watts pour maintenir la température du pot L utilisation d un four à micro ondes ne dure à l ordinaire que quelques minutes parfois à faible puissance Durée de fonctionnement Le diagramme suivant est un ensemble de courbes qui montrent comment la charge de l appar...

Page 12: ...qu ils sont alimentés par une source de 12 volts c c comme une batterie de véhicule ou une configuration à batteries multiples voir le Schéma de configuration permanente de batteries Ce manuel ne décrit pas toutes les configurations possibles Pour optimiser le rendement du convertisseur continu alternatif il faut le placer ou le monter sur une surface plane idéalement une surface de métal qui est ...

Page 13: ...e 12 V c c 6 Raccorder le connecteur serti spécial du câble négatif noir à la borne négative noire sur le convertisseur continu alternatif et serrer les vis de calage contre la partie plate du connecteur 7 Raccorder l anneau de borne du câble négatif noir à la borne négative NEG sur la batterie de 12 V c c ou sur l autre source d alimentation de 12 V c c Quelques étincelles peuvent apparaître lors...

Page 14: ...ns suivantes La première façon consiste en un simple échange chez le détaillant qui l a vendu pourvu qu il s agisse d un détaillant participant Tout retour doit se faire durant la période correspondant à la politique 27 DÉPANNAGE Problèmes audiovisuels communs Guide de protection contre les défaillances et de dépannage MISE SOUS TENSION DU CONVERTISSEUR Problème indication Cause possible Solution ...

Page 15: ...5 volts Fréquence de sortie 58 62 Hz Tension de sortie 120 volts c a Efficacité maximale _ 87 Efficacité sous pleine charge _ 82 Consommation de courant sans charge 0 5A Mise hors tension en présence de surtension 15 5 0 5 volts c c Mise hors tension en présence de faible tension 10 0 0 3 volts c c Réenclenchement auto en cas d arrêt thermique Oui Prises nord américaines standard 2 Calibre de fusi...

Page 16: ...te que si no se evita provocará la muerte o lesiones graves ADVERTENCIA Indica una situación de peligro potencial que si no se evita podría provocar la muerte o lesiones graves PRECAUCIÓN Indica una situación de peligro potencial que si no se evita provocará lesiones leves o moderadas PRECAUCIÓN Cuando se utiliza sin el símbolo de alerta de seguridad indica una situación de peligro potencial que s...

Page 17: ...ente largos o a un calibre insuficiente Por lo tanto el instalador operador debe conocer especialmente los requisitos para mantener seguras tensas e impermeables las conexiones eléctricas y proporcionar alivio de tensión para los cables de CC y el cableado del aparato El aislamiento del cable debe ser el tipo apropiado para el ambiente Refiera a la sección de la instalación de este manual de instr...

Page 18: ...en fuentes de energía o circuitos que no son compatibles con los conversores que utilizan una salida de onda senoidal modificada como este conversor y que pueden dañarse al utilizar este conversor Si su producto requiere una alimentación de entrada de CA de onda senoidal pura para funcionar correctamente es posible que lo indique el manual de instrucciones de su producto En caso de duda debe comun...

Page 19: ... 80 75 90 105 120 135 150 165 180 195 210 235 240 37 evita el voltaje de entrada excesivo en el conversor Aunque el conversor posee protección incorporada contra voltaje en exceso igualmente corre el riesgo de dañarse si el voltaje de entrada excede los 15 5 voltios Las cargas inductivas como televisores y estéreos requieren más corriente para funcionar que las cargas resistivas con la misma clasi...

Page 20: ...ada y 40 C 105 F 3 Debe haber un espacio de al menos 76 mm 3 entre el conversor y otros objetos para permitir el paso de una corriente de aire frío 4 La unidad no debe exponerse al calor directo la luz solar o a vapores explosivos o inflamables y 5 La unidad debe encontrarse lo más cerca posible de la fuente de energía de CC PRECAUCIÓN PARA EVITAR DAÑOS AL CONVERSOR O AL EQUIPO QUE DESEA UTILIZAR ...

Page 21: ... Utilice la antena blindada Conecte la antena con el amplificador 41 ADVERTENCIA PARA REDUCIR EL RIESGO DEL FUEGO DE LA DESCARGA ELÉCTRICA DE LOS DAÑOS MATERIALES O DE LOS DAÑOS CORPORALES NUNCA conecte la unidad directamente con el cableado de la distribución de CA Sugerencias de operación Para lograr un mejor funcionamiento el conversor debe estar en una superficie plana y estable El conversor s...

Page 22: ...na vez excedido el plazo establecido La segunda opción es llevar o enviar el producto con flete pago a un Centro de mantenimiento propio o autorizado de Black Decker para su reparación o reemplazo según nuestro criterio Le pueden solicitar comprobante de compra Encontrará una lista de los Centros de mantenimiento autorizados y de propiedad de Black Decker bajo Herramientas eléctricas Tools Electri...

Reviews: