CAUTION: TO AVOID DAMAGE TO THE INVERTER OR EQUIPMENT USED WITH THE INVERTER:

• Never connect the chassis ground wire from the inverter to the DC negative input.
• CHECK to ensure that the combined loads of the appliances being powered by the inverter DO NOT continuously

exceed the inverter’s wattage rating.

• NEVER place items on or over the inverter during operation.
• MAXX SST™ inverters generate heat during operation and must be placed where cool air can circulate to the

internal fan, and hot air can be removed.

Installation Procedures

When wiring the inverter to a 12 volt DC power source, ensure that polarity is correct. Reversed polarity will
blow a fuse and may cause permanent damage to the inverter. Review “Back View” diagrams on page 4, if
necessary, to identify the location of the DC terminals.

Note:  

The manufacturer’s warranty does NOT cover damage due to reversed polarity. 

Temporary Installation

For Temporary Installation, only use the provided 3 feet long cables each using #2AWG wire terminated with a
ring terminal attached at the battery (power source) end and a Special Crimp Connector attached at the inverter
end. The Special Crimp Connectors are designed for proper connection to the 12 volt input power terminals on
the inverter; connection using any other method is not acceptable.

1. Check to be sure the inverter’s ON/OFF Power Switch is in the OFF position and that no flammable fumes are

present.

2. Locate the Positive (+, POS) and Negative (-, NEG) terminals on the 12 Volt DC battery (or other 12VDC

power source).

3. Locate the Positive (Red, +) and Negative (Black, -) DC input terminal on the inverter.
4. Connect the Special Crimp Connectors of the Positive (Red, +) cable to the Positive (Red, +) terminal on the

inverter and tighten the set screws against the flat side of the connectors.

5. Connect the ring terminal of the Positive (Red, +) cable to the Positive (Red, +) terminal on the 12 Volt DC

battery (or other 12VDC power source).

6. Connect the Special Crimp Connector of the Negative (Black, -) cable to the Negative (Black, -) terminal on

the inverter and tighten the set screws against the flat side of the connector.

7. Connect the ring terminal of the Negative (Black, -) cable to the Negative (-, NEG) terminal on the 12 Volt DC

battery (or other 12VDC power source). There may be some minor sparking when the cable is touched to the
battery terminal.

WARNING:

If persistent, severe arcing occurs between the cable and battery terminals, immediately cease

attempting to make the connection and correct the cause of the problem before continuing.

8. Ensure that all of the electrical connections have been tightened.
9. Set the inverter’s ON/OFF Power Switch to the ON position and verify the Green Power LED Indicator

illuminates and the Red Fault LED Indicator does not illuminate.

10. As a test, plug in a lamp with a 60 or 100 Watt light bulb into one of the inverter’s 120 Volt AC Outlets and

switch the lamp ON. If the lamp lights normally, the inverter is functioning properly and use of the inverter
with other appliances can continue. If the lamp does not light, or does not operate normally:

A. Refer to the “Fault Protection and Troubleshooting Guide” of this Instruction Manual for suggested solutions.
B. If conducting step A does not find and correct the problem, refer to the “Service Information” section of this

Instruction Manual for assistance.

Permanent Installation

The permanent installation of the inverter and the required wiring and safety devices to the 12 Volt DC power
source must be performed by a professional installer. Further requirements are:
1. The inverter is supplied with 2 Special Crimp Connectors to connect the power source wiring to the inverter

DC input terminals. They are designed to be crimped onto #2AWG copper conductor cables (not supplied).

2. The #2AWG power source cables must not exceed 6 feet in length.
3. A 200 Amp ANL Fuse (not supplied) installed in the proper Fuse Holder (not supplied) must be connected in-

line as part of the positive power source input cable as close as possible to the power source connections.

4. A #12AWG insulated wire should be connected between the Grounding Terminal on the inverter (see

“Controls and Functions”, “Back View Diagram” on page 4 ) and the ground terminal on the appliance (such
as a TV or Radio) to minimize electrical noise and reception interference.

CAUTION:

Do not connect this wire to the inverter’s Negative (Black, -) DC input terminals.

9

BATTERY OPERATING TIMES

For example, as shown in the previous graph, using a 400 A/h battery (batteries), if the average power usage will
be 1000 watts, the operating time will be about 150 minutes. A larger capacity battery will deliver more operating
time between recharges.

Note:

The manufacturer recommends conservative estimates when selecting a battery. More amp hours will
deliver a reserve capacity, and a larger capacity battery will not be subject to deep discharges. Ideally, the
number of amp hours (A/h) you expect to use should be less than 50% of the battery’s rated capacity.

Protective Features

LOW BATTERY ALARM
An audible alarm will sound when the 12 volt DC power supply voltage drops down to 10.5 ± 0.3 volts. This
indicates that the battery needs to be charged or there is an excessive voltage drop between the battery power
source and the inverter.

Notes: 

It is normal for the alarm to sound when the inverter is being connected to, or disconnected from, a 12
volt DC power source. This does not indicate a problem. However, if this alarm sounds continuously,
discontinue inverter operation and charge the battery before resuming operation. If the voltage drops to
10.0 volts DC, the inverter will automatically shut down. If the low voltage alarm sounds when the battery
is fully charged refer to the “Troubleshooting” section of this Instruction Manual).

CIRCUIT PROTECTION
The inverter has electronic circuit protection against overload or short circuit conditions.

WARNING: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

If turning the ON/OFF Switch OFF then ON again does not reset the inverter, DO NOT ATTEMPT TO OPEN THE
INVERTER. Opening the inverter for any reason will void the warranty. The unit must be returned to Black &
Decker Manufacturing for testing and repair by professional factory technicians.

INSTALLATION

MAXX SST™ inverters will provide you with continuous electrical power when powered by a 12 volt DC source,
such as a vehicle battery or a multiple battery configuration (see the “Permanent Battery Configuration
Diagram”). This manual does not describe all of the possible configurations.
For optimum operation, the inverter should be placed or mounted on a flat surface; ideally, a normally cool metal
surface to help diffuse the heat that is generated. Two cables (see the “Battery Configuration Diagram”) are not
supplied, but will be required to allow for full power operation and to provide flexibility in positioning the inverter.

Operating Environment

Do not locate inverters in an area, room or compartment where explosives or flammable fumes might be present,
such as engine rooms, engine compartments, or small, unvented battery compartments.
To avoid possible dangerous conditions, the inverters must be located where:

1.The unit is kept dry;
2.Air temperature is between 30°F (–1°C), non-condensing, and 105° F (40°C);
3.At least three inches of clearance from other objects is maintained for cooling airflow;
4.The unit is not exposed to direct heat, sunlight or to explosive or flammable fumes; and
5.The unit is as close to the DC power source as possible.

Watts

Power Level

Amps

  100    10

  200    20

  300    30

  400    40

  500    50

  600    60

  700    70

  800    80

  900    90

1000 100

  50 A/h

120 A/h

200 A/h

400 A/h

OPERATING TIME CHART FOR LOAD AND BATTERY CAPACITY AVAILABLE

Minutes   15    30    45   80    75    90   105 120  135  150  165  180  195  210  235  240

8

90550750 VEC049DCB GOOD ONE.qxp  6/5/09  1:46 PM  Page 8

Summary of Contents for Marine Battery

Page 1: ...ww BlackandDecker com NewOwner to register your new product PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON If you have a question or experience a problem with your Black Decker purchase go to HTTP WWW BLACKANDDECKER COM INSTANTANSWERS If you can t find the answer or do not have access to the internet call 1 800 544 6986 from 8 a m to 5 p m EST Mon Fri to speak with an agent Please have t...

Page 2: ...avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used without the safety alert symbol indicates potentially hazardous situation which if not avoided may result in proper...

Page 3: ...might have opened as a result of trying to use it with the inverter The product exhibits unusual operation such as intermittent operation buzzing and the like WARNING If the product does not operate normally to reduce the risk of injury or property damage Turn the product off immediately and unplug it from the inverter SINEWAVE MODIFIED SINE WAVE 5 4 CAUTION TO AVOID DAMAGE TO THIS INVERTER OR EQU...

Page 4: ...r in amperes affects runtime These curves are only estimates of operating time dependent upon The condition of the batteries The state of charge on the batteries The amount of other DC appliances drawing current from the batteries Three curves were developed for a battery of 50 Ampere Hours AH capacity and three for multiple batteries in parallel The higher capacity curves are for 120 AH 200 aH an...

Page 5: ...ust not exceed 6 feet in length 3 A 200 Amp ANL Fuse not supplied installed in the proper Fuse Holder not supplied must be connected in line as part of the positive power source input cable as close as possible to the power source connections 4 A 12AWG insulated wire should be connected between the Grounding Terminal on the inverter see Controls and Functions Back View Diagram on page 4 and the gr...

Page 6: ... cycle marine batteries The DC power source may also be two 12 volt batteries connected in parallel On larger applications the power source may be several batteries connected in parallel as shown in the following Permanent Battery Configuration diagram Note For typical heavy duty uses in a Permanent Installation an ANL fuse must be added as close as possible to the power source battery positive te...

Page 7: ...essory not recommended for use with this tool could be hazardous SERVICE INFORMATION All Black Decker Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool service Whether you need technical advice repair or genuine factory replacement parts contact the Black Decker location nearest you To find your local service location refer to the yellow...

Page 8: ...es graves ÉVITER LES ENVIRONNEMENTS DANGEREUX Ne pas utiliser le convertisseur continu alternatif dans un endroit humide ou mouillé Ne pas utiliser le convertisseur continu alternatif sous la pluie TENIR LES ENFANTS À L ÉCART Tous les visiteurs doivent se tenir éloignés de la zone de travail RANGER LES CONVERTISSEURS CONTINU ALTERNATIF INUTILISÉS À L INTÉRIEUR Lorsqu il n est pas utilisé le conver...

Page 9: ... un port destiné à recevoir une télécommande vendue séparément Un courant alternatif de 120 volts est fourni par quatre prises triphasées nord américaines Les prises peuvent recevoir des fiches pour courant alternatif à deux ou trois broches 17 NE PAS UTILISER de convertisseur continu alternatif ou d appareils électriques à proximité de liquides inflammables ou dans une atmosphère gazeuse ou explo...

Page 10: ... du Maxx SST Voici quelques unes des caractéristiques automatiques intégrées Mise hors tension à la suite d une surcharge ou d une surchauffe qui s active si la puissance nominale est dépassée au secteur Mise hors tension avec court circuit sur secteur Avertisseur sonore de faible tension émis à une tension d entrée de 10 5 volts Mise hors tension en présence de faible tension s active à 10 0 volt...

Page 11: ...e Par exemple une cafetière domestique ordinaire consomme 500 watts pendant l infusion environ 5 minutes mais il ne faut qu environ 100 watts pour maintenir la température du pot L utilisation d un four à micro ondes ne dure à l ordinaire que quelques minutes parfois à faible puissance Durée de fonctionnement Le diagramme suivant est un ensemble de courbes qui montrent comment la charge de l appar...

Page 12: ...qu ils sont alimentés par une source de 12 volts c c comme une batterie de véhicule ou une configuration à batteries multiples voir le Schéma de configuration permanente de batteries Ce manuel ne décrit pas toutes les configurations possibles Pour optimiser le rendement du convertisseur continu alternatif il faut le placer ou le monter sur une surface plane idéalement une surface de métal qui est ...

Page 13: ...e 12 V c c 6 Raccorder le connecteur serti spécial du câble négatif noir à la borne négative noire sur le convertisseur continu alternatif et serrer les vis de calage contre la partie plate du connecteur 7 Raccorder l anneau de borne du câble négatif noir à la borne négative NEG sur la batterie de 12 V c c ou sur l autre source d alimentation de 12 V c c Quelques étincelles peuvent apparaître lors...

Page 14: ...ns suivantes La première façon consiste en un simple échange chez le détaillant qui l a vendu pourvu qu il s agisse d un détaillant participant Tout retour doit se faire durant la période correspondant à la politique 27 DÉPANNAGE Problèmes audiovisuels communs Guide de protection contre les défaillances et de dépannage MISE SOUS TENSION DU CONVERTISSEUR Problème indication Cause possible Solution ...

Page 15: ...5 volts Fréquence de sortie 58 62 Hz Tension de sortie 120 volts c a Efficacité maximale _ 87 Efficacité sous pleine charge _ 82 Consommation de courant sans charge 0 5A Mise hors tension en présence de surtension 15 5 0 5 volts c c Mise hors tension en présence de faible tension 10 0 0 3 volts c c Réenclenchement auto en cas d arrêt thermique Oui Prises nord américaines standard 2 Calibre de fusi...

Page 16: ...te que si no se evita provocará la muerte o lesiones graves ADVERTENCIA Indica una situación de peligro potencial que si no se evita podría provocar la muerte o lesiones graves PRECAUCIÓN Indica una situación de peligro potencial que si no se evita provocará lesiones leves o moderadas PRECAUCIÓN Cuando se utiliza sin el símbolo de alerta de seguridad indica una situación de peligro potencial que s...

Page 17: ...ente largos o a un calibre insuficiente Por lo tanto el instalador operador debe conocer especialmente los requisitos para mantener seguras tensas e impermeables las conexiones eléctricas y proporcionar alivio de tensión para los cables de CC y el cableado del aparato El aislamiento del cable debe ser el tipo apropiado para el ambiente Refiera a la sección de la instalación de este manual de instr...

Page 18: ...en fuentes de energía o circuitos que no son compatibles con los conversores que utilizan una salida de onda senoidal modificada como este conversor y que pueden dañarse al utilizar este conversor Si su producto requiere una alimentación de entrada de CA de onda senoidal pura para funcionar correctamente es posible que lo indique el manual de instrucciones de su producto En caso de duda debe comun...

Page 19: ... 80 75 90 105 120 135 150 165 180 195 210 235 240 37 evita el voltaje de entrada excesivo en el conversor Aunque el conversor posee protección incorporada contra voltaje en exceso igualmente corre el riesgo de dañarse si el voltaje de entrada excede los 15 5 voltios Las cargas inductivas como televisores y estéreos requieren más corriente para funcionar que las cargas resistivas con la misma clasi...

Page 20: ...ada y 40 C 105 F 3 Debe haber un espacio de al menos 76 mm 3 entre el conversor y otros objetos para permitir el paso de una corriente de aire frío 4 La unidad no debe exponerse al calor directo la luz solar o a vapores explosivos o inflamables y 5 La unidad debe encontrarse lo más cerca posible de la fuente de energía de CC PRECAUCIÓN PARA EVITAR DAÑOS AL CONVERSOR O AL EQUIPO QUE DESEA UTILIZAR ...

Page 21: ... Utilice la antena blindada Conecte la antena con el amplificador 41 ADVERTENCIA PARA REDUCIR EL RIESGO DEL FUEGO DE LA DESCARGA ELÉCTRICA DE LOS DAÑOS MATERIALES O DE LOS DAÑOS CORPORALES NUNCA conecte la unidad directamente con el cableado de la distribución de CA Sugerencias de operación Para lograr un mejor funcionamiento el conversor debe estar en una superficie plana y estable El conversor s...

Page 22: ...na vez excedido el plazo establecido La segunda opción es llevar o enviar el producto con flete pago a un Centro de mantenimiento propio o autorizado de Black Decker para su reparación o reemplazo según nuestro criterio Le pueden solicitar comprobante de compra Encontrará una lista de los Centros de mantenimiento autorizados y de propiedad de Black Decker bajo Herramientas eléctricas Tools Electri...

Reviews: