Installation Manual
Fingerprint scanner and code keypad
2 Version installed in door
2.1 Installation in timber/steel doors
In order to install the module, it is necessary to cut out a recess with the dimensions 38 x 50
mm and a depth of 45 mm. The recommended installation height of the module is between
1.2 and 1.4 m above finished floor level.
The connecting cable must be routed within the door leaf (e.g. through suitable grooves) to
the installation cutout of the module.
The module is screwed into the door leaf from the front using the 2.2 x 19 screws provided.
The decorative closing profile is then glued on. The adhesive strips required for this are on
the inside of the closing profile.
Depth
Milling dimensions
up to R4
1200 up to
1400 above
fixed floor
level
Thickness
Installation Manual, edition 3 dated 02/01/2013
Page 25
Copyright © BKS GmbH, 2012. All rights reserved.
C 59 501 107