Installation Manual
Fingerprint scanner and code keypad
Connection example for electrical door opener
Connection example for Secury with A-opener
1
2
1 2 3 4
1 2 3
1 2 3
Power
-
supply
Reader
Relay 1
Relay 2
Brown (+ 12/24V)
Black (control)
Grey (GND)
Inside unit
GND
+ 12/24V
Secury
with
A-opener
DC 12/24 V
Power supply unit
1
2
1 2 3 4
1 2
3
1 2 3
Inside unit
Relay 1
Relay 2
Reader
-
Power
supply
Electric
strike
8 –
8 –
12 V AC
or
24 V DC
Power supply unit
Installation Manual, edition 3 dated 02/01/2013