Installation Manual
Fingerprint scanner and code keypad
1 Technical Data
Version for installation in door
In-wall/on-wall version
Dimensions of outside unit
(WxHxD)
44x75x29 mm
80.5x80.5x30 mm
(55x55x30 mm without frame)
Fingerprint scanner sensor
ATMEL Fingerchip™ line sensor
Operating voltage
DC 8..24 V
DC 8..30 V, AC 8..12 V
Power consumption
approx. 1 W
1 W, in peaks 3 W
Relay output
via SECUREconnect
AC/DC 24 V, 5.0 A
Operating temperature
-20..+85°C
Storage temperature
-25..+85°C
Moisture resistance
up to 95% relative humidity
IP class
IP 56 (outdoor use)
Battery for programming
device
CR2032
Template accumulator
150 finger templates / 20 user codes
Scanning duration
template
approx. 1 s
Identification duration
template
approx. 10 ms per comparison
Incorrect rejection rate
(FRR)
approx. 0.5%
Incorrect acceptance rate
(FAR)
between 0.00001 and 0.000001
(with FRR 0.5%)
CE declaration of
conformity
in accordance with EC Directive 2002/95/EC
Door opening behaviour
(only version installed in
door)
If the door is opened for longer than 12 s, the sensor module is shut
down. If these shutdown periods are brief, the fingerprint scanner sen-
sor reaches its optimum operating temperature within 3 to 5 seconds.
If the door has been open continuously for longer than 10 minutes, it
takes between 15 and 20 seconds for the fingerprint scanner sensor to
reach its optimum operating temperature. In this warm-up phase, the
finger may not be detected (rejection with red LED). If this is the case,
please drag your finger across the sensor again. The code keypad
does not require a warm-up period following a shutdown.
The saved fingerprints or door opening user codes (templates) are
retained in the event of a power failure.
Installation Manual, edition 3 dated 02/01/2013
Page 24
Copyright © BKS GmbH, 2012. All rights reserved.
C 59 501 107