Installation Manual
Fingerprint scanner and code keypad
2.3 Installation in combination with Secury (A-opener)
In order to install the module, a cutout with the dimensions 38 x 66 mm and a depth of
45 mm is required. The recommended installation height of the module is between 1.2 and
1.4 m above finished floor level.
The connecting cable must be routed within the profile to the installation cutout for the
module.
The module is screwed sideways from the rebate into the profile using the enclosed 3.9 x 50
screws. It may be necessary attach the mounting frame to the module rotated through
through 180°. The fastening hole with the larger diameter must always face in the direction of
the rebate.
The lateral fastening position from the front of the profile can be varied between 18.7 and
25.3 mm via the oblong holes of the fixing bracket.
Be careful to ensure that the lateral fastening in the profile groove does not collide with the
connecting rod or the Secury attachment points.
Finally, glue on the decorative closing profile. The adhesive strips required for this are on the
inside of the closing profile.
Optional steel plate (enclosed)
90° countersink is sufficient for
min. 3 mm profile thickness
1200 up to
1400 above
fixed floor
level
Faceplate plus Secury
connecting rod
Install hole with smaller diameter far
away from the screw head
Screw is self-tapping
Installation Manual, edition 3 dated 02/01/2013
Page 27
Copyright © BKS GmbH, 2012. All rights reserved.
C 59 501 107