Serial Trigger and Decode
78
Operation Steps
1. Touch
Setup
to enter the
TRIGGER
function menu.
2. Touch
Type
and select
Serial
.
3. Touch
Protocol
and select
CAN
.
4. Touch
Trigger Setting
to enter the
CAN TRIG SET
menu.
5. Touch
Condition
and select the trigger condition by turning the
Universal Knob
:
• If you select the
REMOTE
and
ID
condition:
a. Touch
ID Bits
to set the length of ID (11bits or 29 bits).
b. Touch
Curr ID Byte
and turn the
Universal Knob
to select the byte that you want to set.
c. Touch
ID
and set the ID’s value by turning the
Universal Knob
. (Tips: In order to make is convenient for
the operator to set the parameters, ID b is split into several bytes. For example, if the ID’s length is 11 bits,
it will be split into two bytes, a byte includes 8 bits. If “1st byte” is selected, only the 8 least significant bits
can be changed.)
• If you select the
ID+DATA
condition:
a. Touch
ID
bits to select the ID’s length (11 or 29 bits).
b. Touch
Curr ID Byte
and turn the
Universal Knob
to select the byte that you want to modify.
c. Touch
ID
and set the ID’s value by turning the
Universal Knob
.
d. Touch
Data
and set the value of the first byte by turning the
Universal Knob
.
Figure 7.25
CAN Trigger