Page 2
3.3
Electrical connections
4.1
Switching on and factory setting
Configuration mode
Most important settings
Displays on the detector
4.2
4.3
4.4
4.5
Explanations
Establishing the connection to the remote control
grey
yellow
green
brown
white
pink
blue
red
Relay 1
48 V AC / DC
55 VA / 24 W
12–28 V AC / 12–36 V DC
12–28 V AC / 12–36 V DC
Relay 2
48 V AC / DC
55 VA / 24 W
4
Settings
After the supply voltage has been connected, the red LED signals
"Start-up" by flashing.
The factory setting is suitable for the following applications:
– Mounting height 4.0 to 4.9 m
– Relay hold interval 2 s
– Slow motion detection switched off
– Differentiation between people and vehicles active
– Crossing traffic optimisation switched off
– Detection of movements towards the detector (forwards)
The factory settings can be restored at any time using the remote
control (A+9)!
Press key G on the remote control. If the connection has been established suc-
cessfully, G and one of the keys 1 to 7 light up (address of the detector).
If G flashes, the connection could not be established.
➔
Hold the remote control closer to the detector and point directly at it.
➔
Check the batteries in the remote control.
General:
Flashing keys
on the remote control mean that the Herkules 2 has not
stored the programming that has been performed
.
Steady lit keys
on the remote control mean that the value has been
accepted and stored by Herkules 2.
The connection between the remote control and Herkules can only be
established when the detector is in configuration mode. Configuration
mode is activated when the detector is switched on. This is deactivated
automatically 30 minutes after the last setting has been made.
Configuration mode can be activated by:
– Pressing any key on detector (x or y)
– Interrupting electrical power supply
– Via access code on remote control
Start-up phase
SMD = Slow Motion Detection
The slightest (quasi-static) movements are detected as soon as the
industrial door opens. The industrial door is only closed if no more
movement is registered during the set monitoring time.
CTM = Crossing traffic masking
Crossing traffic masking prevents an industrial door from being
inadvertently opened by objects that are only moving or walking past it
but do not want to pass through.
P/V identification
Using this function, it is possible to select whether the relay outputs
should be switched separately in response to people or vehicles (see
table of relay parameter settings).
1.
Select enhanced level (
C+1…8
)
2.
Set mounting height (
F+4+1…7
) if different from factory setting
Important: The detector will not function correctly if the
wrong mounting height is set
3.
Set field size (
D+1…9
) if necessary using inclination angle, 0–90°,
in 15° steps
+
–
+
–
Red LED
Flashes several times during start-up, first slowly
then quickly.
Numerical keys
to
1
9
Battery
compartment
Infrared interface
Function keys
to
F
A
Locking
screw
Start
G
Front side
Rear side
Green LED
Lights up on detection, relay 2 is activated.
Green LED
Flashes on detection in the SMD field.
Red LED
Lights up on detection, relay 1 is activated.
Configuration
Green LED
Indicates the parameter (function no.) by the
frequency of flashing.
Red LED
Indicates the parameter level by the frequency of
flashing.
Operation
Configuration mode can only be activated with the remote control if a
code has been stored previously (see access code).
1.
Press start key G
➔
G
and one of the keys
1...7
light up
2.
Press
C
then
9
➔
C
and
1
light up
➔
Access code function is switched on
3.
Enter four-digit code 1111 - 9998
4.
Press C
➔
C
and
1
light up
➔
Configuration mode is activated
➔
Detector is ready for programming
➔
If
C
and
2
light up, code was incorrect
➔
Start again from step 1