• To stop dispensing within 10 seconds, press the       button again.

2

Press the      button again to dispense water

1

Press the      button to unlock

• When the DISPENSE light is off, water cannot be 

   dispensed.

The DISPENSE green light blinks, the 

function is unlocked and water can be 

dispensed now. 

Activate dispensing with a gentle touch 

on the      button again within 3 sec after 

Unlocking. The “DISPENSE” green light 

remains "on" during water dispensing.

3 seconds

Dispensing Hydrogen Water

Blinks

Steady ON

*Right after dispensing, the DISPENSE light turns off and the Dispense Lock is activated.

Automatic Dispense Stop

Press once the       button provides a 10-second dispensing and it will stop automatically. 

[Approx. 250ml (±10%) ] 

• If no water is dispensed, the Dispense Lock is activated after 3 seconds. 

*Do not tilt or shake the product after dispensing. Water may drip from the Spout, causing 

scalds if the water is hot.

Dispense Lock

An automatic safety function to prevent water from dispensing if the       button is accidentally 

pressed.

Summary of Contents for EOS7150-H

Page 1: ... for purchasing this Biolux product Please read the instructions carefully and follow the safety precautions when using this product Before using this product please pay special attention to the IMPORTANT SAFEGUARDS P 2 4 This product is intended for household use only ...

Page 2: ...tion Heating Function Dispensing Hydrogen Water How to Dispose Water How to Connect Cannula Hydrogen Inhalation EOS7150 HG exclusive LED Effect Info Setting System Menu Settings Cleaning Maintenance Q A on Product Use Troubleshooting 1 2 3 4 5 6 7 8 9 10 The illustrations used in this Instruction Manual may vary from the actual product that you have purchased 1 P 21 Gas Delivery Hydrogen Inhalatio...

Page 3: ...fants from putting the plug into their mouth 4 Close supervision is recommended when the appliance is used by or near children Do not pour water directly from the tap Do not put the unit in a sink or allow it to get wet Do not turn the unit upside down when the bottom is wet 3 To safeguard against fire electric shock and possible injury keep the power cord plug and the appliance away from water or...

Page 4: ...r device into the same outlet Plugging other devices into the same outlet may cause the electrical outlet to overheat resulting in fire If the blades or surface of the Power Plug become soiled wipe them clean A dirty Power Plug may cause fire Do not use a power supply voltage other than being specified on the product Use of any other power supply voltage may cause fire or electric shock Stop using...

Page 5: ... Water Level Line Do not let the unit fall over Do not lift tilt or shake the unit or carry it by the lid Close the Upper Lid securely Do not slam the Upper Lid when closing Avoid rough handling dropping or bumping the product Do not use the product near a heat source or on top of induction heating cookers Do not allow water to come into contact with the Control Panel Steam may result in scalds if...

Page 6: ...with the cell As this is consumed it must be refilled from time to time as required To ensure the product meets our high expectations with regards to reliability and performance we have tested this model extensively at our manufacturing plant to ensure reliability and longevity of the unit Other features include The of EOS7150 HG model provides a source of high purity hydrogen gas for inhalation S...

Page 7: ...50 65 80 122 149 176 185 x 290 x 330 mm No by products Hypochlorous Acid Ozone Dissolved concentrations of hydrogen in water and ORP may vary according to water quality and temperature 3 kg approx NA 12 ml min Features Capacity Voltage Rated Power Hydrogen Production Purity Heating Temperatures External Dimensions W x D x H Net Weight Safety Qualifications Hydrogen Water Hydrogen Gas 6 Concentrati...

Page 8: ...et Provide sealing to maintain pressure for hydrogen dissolution Prevent water leak when tilted Front Lid Lid Latch Filter Lever Filter Cartridge For care and use instructions see pg 24 Body Maximum Water Level Pure Water Chamber Collect pure water for electrolysis in here Vent oxygen here Control Panel Inner Container Borosilicate Hard Glass Water Level Window Power Cord The shape of plug differs...

Page 9: ...ction see pg 15 Also used for Resuming Peak Production After HEATING light START light MENU button Press to perform Menu Functions see pg 22 DISPENSE button Press once to Unlock then press again to dispense water see pg 18 MENU light DISPENSE light EOS7150 H GAS DELIVERY MENU button Start Hydrogen Gas Timer see pg 20 Also used to perform Menu Functions see pg 22 GAS DELIVERY MENU light EOS7150 HG ...

Page 10: ...Filter Chamber is used exclusively in the electrolysis for hydrogen production for which the higher the water purity the better the sustainability of the performance Although the Filter inside is to provide purification it is important to use water with proper purity levels to sustain the performance Please adhere to the operating guidelines for the water that is to be added into the Filter Chambe...

Page 11: ...uality Do not pour anything other than water into the product When using mineral or alkaline ionized water or hard water 180ppm CaCO3 When mineral water alkaline ionized water or hard water is used after heating a floating residue or a milky white substance may form on the surface of the Inner Container This is due to the minerals in the water and is harmless to your health Frequent cleaning is re...

Page 12: ...very restart 4 To change the language afterwards please see pg 23 for further instructions Remove the Spout cap and plug the product to a standard AC outlet The product takes 10 sec to start up 3 Assemble the Filter Lever onto the Filter Cartridge Open the Front Lid and attach the Filter Cartridge at the bottom of the Filter Chamber 2 Initial Use ...

Page 13: ...Lid and fill the Inner Container with quality filtered water to the MAX line 6 MAX line Please refer to pg 10 for the operating guideline for the water to be added to the Inner Container Do not pour water directly from a tap or place the product on a wet surface such as a sink Do not fill above the MAX line Pour in water with a pitcher bottle or another container Max 1800ml Standby ready Ensure Fr...

Page 14: ...cts Blue means Ready Press once on the button 13 Produce Hydrogen Water Hydrogen Water Production ON During Standby Heating Function The first time you use the new product you may notice the smell of plastic This is normal and will gradually go away Be sure to attach the Filter Cartridge fill the Filter Chamber and Inner Container with the proper required quality of water to the MAX line before pr...

Page 15: ...s saturated status automatically Blinks Blinks Reduced amount and or having smaller sizes of bubbles during period of Automatically Maintaining Peak Concentration is normal The system is programmed to reduce the unnecessary peak production after 30 minutes from the initial start Each time the hydrogen water production function is activated the system will provide 3 hour uninterrupted hydrogen prod...

Page 16: ...r Production ON Automatically Maintaining Peak Concentration Steady ON Light OFF 3 seconds 1 The Heating green light blinks slowly the function is unlocked for 3 seconds If the Heating Function is not triggered the Heating Lock is activated after 3 seconds Heating Lock An automatic safety function to avoid unwanted heating if the button is accidentally pressed Do not activate the Heating Function ...

Page 17: ... Temperature Settings 21 C 50 C 70 F 122 F Current Temperature Set Temperature Press the button twice to change temperature settings PS the first press is to unlock the function Under Standby or Heating Mode Press once to unlock Change the temperature settings with a gentle touch on the button again within 3 sec after unlocking In 3 seconds Every press on can change the heating settings as shown i...

Page 18: ... water in the Inner Container and there is a detection of 3 C 7 F reduction during the Heating Function is on the system will reactivate the Resuming Peak Production automatically The production time will be rescheduled for a new 15 minutes to re enrich the hydrogen water concentration to peak How to do Unplug the pot and wait till the temperature to cool before re plug Note Frequent overheat may ...

Page 19: ...mains on during water dispensing 3 seconds Dispensing Hydrogen Water Blinks Steady ON Right after dispensing the DISPENSE light turns off and the Dispense Lock is activated Automatic Dispense Stop Press once the button provides a 10 second dispensing and it will stop automatically Approx 250ml 10 If no water is dispensed the Dispense Lock is activated after 3 seconds Do not tilt or shake the produ...

Page 20: ... the Drip Grid and Tray 3 Remove the Drain Tube Cap and drain all the electrolysis water out Pour in water with a pitcher bottle or another container to the MAX line Attach your cannula on the Cannula Connector Enjoy hydrogen inhalation Insert the Cannula Connector into the Lid Vent 4 Hold the product with both hands and dispose all remaining water 5 Dispense as much water out as possible 1 1 How ...

Page 21: ...Hydrogen Water Production 30 00 60 00 Timer OFF Default This is a function available exclusively to EOS7150 HG 21C Hydrogen Lv 1200 ppb Peak 21C Hydrogen Lv 1200 ppb Peak Gas Delivery Timer OFF Press once on the button to stop the function Automatic OFF based on timer settings or Resume Hydrogen Water Production Steady ON ...

Page 22: ... has started 60 00 alternative is available by pressing the button one more time When Service or Maintenance Is Required When is shown It indicates consumable part s replacement is due including 1 Filter Cartridge is due and the replacement is required 2 Hydrogen Cell is due or damaged and the replacement is required When the above information is noted please refer to page 23 to proceed to status ...

Page 23: ...andby Enter System Menu In EOS7150 HG Select Resume to return the standby mode Select LED Effect to turn on off the lighting effects Select Info Setting to enter system information and replacement reset LED Effect ON OFF Select LED Effect to turn ON and OFF the lighting effects Resume to Standby once completed 22 ...

Page 24: ...enter reset options System will resume to standby after the reset is completed Select Temperature to change Temperature unit settings In good condition Service due remaining life less than 2 or has finished or a failure has been detected 1 3 4 2 Filter life end Replace as needed DISPLAY Hydrogen Cell life end Replace as needed DISPLAY Hydrogen Cell malfunction Replace as needed DISPLAY 23 Explanat...

Page 25: ...e found on the surface calcium scaling White or glittering floating materials are found in the water crystals or minerals Slimy residues are found on the surface or in the water biofilm Water has an odor biofilm See pg 25 for how to perform Citric Acid Cleaning The condition of the Inner Container may vary depending on the water quality and frequency of use Pure Water Chamber Filter Chamber Filter...

Page 26: ...irst Pour it into the Inner Container and fill with clean water to the MAX line 2 Close the Upper Lid then press START button for 10 seconds to activate the Cleaning function 3 Dispense the water to clean the water dispenser Refill clean water in the Inner Container to the MAX line and repeat the dispense operation as many times as needed until the smell of the citric acid is removed throughly 4 D...

Page 27: ...ter Chamber with Pure RO water Remove the Filter Chamber and adjust the floater at the bottom of Pure Water Chamber Call customer service for repair Call customer service for repair Call customer service for repair Unplug the unit replace with room temperature water Reconnect the unit after it cool down Solution No Display Water is not hot Electronic failure Electronic failure 3 hour Automatic Hea...

Page 28: ...0ppb the Automatically Maintaining Peak Concentration function will be turned on automatically At this point reduced bubbling is normal Solution Observed no bubbling Observed reduced bubbling Water does not dispense or does not pour smoothly Water has an unpleasant odor or a strong odor of chlorine Some filmy milky white residues is observed Electronic failure No power or the Power Plug is not con...

Page 29: ...g reconnect after 30 seconds and operate it again Q A ON PRODUCT USE Is is okay to use the product for liquids other than water Do not fill the product with any liquid other than water It may cause malfunction To prevent scale from building up please change the water at least once a day Yes However when mineral water is used a floating residue may develop or milky white substance may form on the s...

Page 30: ...MEMO ...

Page 31: ...MEMO ...

Page 32: ...Biotek Environmental Science Ltd www besgroups com Rev A202008_EN_BES ...

Reviews: