GUARANTEE
Please keep your receipt as this will be required
for any claims under this guarantee.
This appliance is guaranteed for 2 years after
your purchase as described in this document.
During this guaranteed period, if in the unlikely
event the appliance no longer functions due to
a design or manufacturing fault, please take it
back to the place of purchase, with your till
receipt and a copy of this guarantee.
The rights and benefits under this guarantee
are additional to your statutory rights, which are
not affected by this guarantee. Only Holmes
Products (Europe) Ltd. (“Holmes”) has the right
to change these terms.
Holmes undertakes within the guarantee period
to repair or replace the appliance, or any part of
appliance found to be not working properly free
of charge provided that:
• you promptly notify the place of purchase
or Holmes of the problem; and
• the appliance has not been altered in any
way or subjected to damage, misuse,
abuse, repair or alteration by a person
other than a person authorised by
Holmes.
Faults that occur through, improper use,
damage, abuse, use with incorrect voltage, acts
of nature, events beyond the control of Holmes,
repair or alteration by a person other than a
person authorised by Holmes or failure to follow
instructions for use are not covered by this
guarantee. Additionally, normal wear and tear,
including, but not limited to, minor discoloration
and scratches are not covered by this
guarantee.
The rights under this guarantee shall only apply
to the original purchaser and shall not extend to
commercial or communal use.
Waste electrical products should
not be disposed of with
Household waste. Please recycle
where facilities exist. E-mail us at
[email protected]
for further recycling and WEEE
information.
Holmes Products (Europe)
Limited
1 Francis Grove
London
SW19 4DT
UK
FELICITATION
En sélectionnant un humidificateur Bionaire
TM
,
vous avez choisi l’un des meilleurs humidificateurs
sur le marché.
VEUILLEZ LIRE ET CONSERVER CE
MODE D’EMPLOI.
DESCRIPTION GENERALE
(VOIR FIG. 1/2)
A
Volume de vapeur
B Voyant indiquant que l’appareil est en
marche
C Bouton de contrôle de l’humidité
D Base
E Réservoir
d’eau
F Poignée de transport du réservoir
G Couvercle du réservoir à remplir d’eau
CONSIGNES DE SECURITE
IMPORTANTES
Veuillez lire ce manuel attentivement avant
d’utiliser cet appareil, car une utilisation correcte
vous assure la meilleure performance.
Lorsque vous utilisez des appareils électriques,
prenez toujours des précautions de sécurité de
base, en particulier les suivantes :
•
Lisez toutes les instructions avant d’utiliser
l’appareil.
•
Exercez une surveillance étroite lorsque
l’appareil est utilisé à proximité d’enfants.
Gardez l’appareil hors de portée des enfants.
•
L’appareil doit être utilisé par un adulte
capable.
•
Débranchez l’appareil de la prise murale
lorsque vous ne l’utilisez pas, pour ajouter
ou retirer des pièces et avant de le nettoyer.
•
N’utilisez pas l’appareil si le cordon électrique
ou la prise d’alimentation sont détériorés,
si l’appareil est défectueux ou s’iI est tombé
ou a été endommagé de quelque façon que
ce soit. En cas de détérioration du fil
électrique, faites-le remplacer par le
fabricant ou un représentant du service
après-vente pour éviter tout danger.
•
L’utilisation d’accessoires non recommandés
ou non vendus par Bionaire
TM
peut provoquer
un incendie, un choc électrique ou des
blessures.
•
N’utilisez pas l’appareil à l’extérieur.
•
Ne laissez pas le fil électrique pendre par
dessus le bord d’une table ou d’un comptoir,
ou entrer en contact avec des surfaces
chaudes telles qu’une cuisinière.
•
Utilisez cet appareil uniquement pour les
usages pour lesquels il a été conçu.
STORAGE TIPS
If you do not plan to use your unit for an extended
period of time, (i.e. during the summer months), it
is important that you follow these instructions to
help prevent stagnation of water in the unit.
1.
Turn the unit off and disconnect from the
outlet. Remove the water tank, then empty
the tank and the base completely. Clean the
humidifier as instructed in the cleaning
instruction section.
2.
Dry the unit thoroughly. DO NOT leave any
water in the unit when storing.
3.
Pack the humidifier in its original carton and
store in a cool, dry place.
For U.K. and Ireland only:
If the plug is not suitable for the socket outlets in
your home, it can be removed and replaced by a
plug of the correct type. Please refer to
"Installation of a plug" below.
Installation of a plug
Applicable to U.K. and Ireland
The wires in the mains lead are coloured as such:
BROWN
-
LIVE
BLUE
-
NEUTRAL
Please note that the colour of these mains wires
may not correspond with the colour markings
that identify the terminals in your plug. Please
proceed as follows:
The BROWN coloured wire must be connected
to the terminal, which is marked with the letter
"L" or is coloured RED.
The BLUE coloured wire must be connected to
the terminal, which is marked with the letter "N"
or is coloured BLACK.
DO NOT CONNECT either of these wires to the
earth terminal in the plug. The earth terminal plug
is marked with the letter "E", or with the earth
symbol
or coloured GREEN and YELLOW.
NOTE:
If the terminals in the plug are not
marked or if you are unsure or in doubt about
the installation of the plug please contact a
qualified electrician. If a 13A 3-pin plug is fitted,
it must be an ASTA approved plug, conforming
to BS1363 standard. Replacement 3A fuse must
be BSI or ASTA BS1362 approved.
PROBLEM
CAUSE
SOLUTION
Power light is off.
Humidifier is not plugged in or
humidity control switch is on the
off (
) position.
Plug into power socket and turn the
humidity control switch clockwise.
No water in tank. Humidity
control switch is on the
off (
) position.
Fill the tank with water. Turn the humidity
control switch clockwise.
Mist has bad odour.
The machine is new or the
water is not clean.
Open the water tank and place the
appliance in a cool area for 12 hours. Wash
the tank out or change the water.
Power light is on but
no mist being emitted.
The water level is too high.
Pour some of the water from the water
tank inlet and replace the tank.
Little mist being
emitted.
The humidity control has scale,
the water is dirty or has not
been changed for some time.
Wash the humidity control and change the
water.
TROUBLESHOOTING
Clean the transducer softly with a damp
cotton ball. Transducer surface is delicate,
avoid applying excessive pressure.
Scale covers the transducer
3 amp
5
Humidity level is set too low.
Select a humidity setting between the Min
(
) and Max (
) humidity range.
Increase the humidity level by turning the
Humidity Control Knob from Min (
) to
Max (
).
Humidity level is set too low.