Bionaire BU3000 Instruction Manual Download Page 2

Do not use humidifier in an area where
humidity level is in excess of 55%.

This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.

PRE-OPERATING INSTRUCTIONS

1.

Be sure the humidifier is disconnected from
the wall outlet and humidity control switch
(C) is in the off position (

).

2.

Place the base (D) where you want the unit
to operate. Then, take the tank (E) off the
unit to refill it (without moving the base).

3.

Remove the tank lid (G) and fill with cool,
fresh tap water.

4.

Replace the lid.

5.

Place the water tank (E) on the base (D).

6.

Ensure humidifier is level. If the humidifier is
not level always turn the power off before
handling it.

NOTE:

Do not fill the water directly into the

base (D).

OPERATING INSTRUCTIONS 

1.

Plug the power cord into a convenient
electrical outlet.

2.

Power on light indicator (B) will illuminate
when the unit is connected to main electrical
power and operating. When the unit is out of
water or when the unit is switched off, the
Power on light indicator will not be working.

3.

Turn your humidifier on by rotating the
humidity control switch (C) to the high
position (

) It will take a few minutes before

full moist air output is obtained. Please note
the mist may not be visible straight away at
the low setting.

4.

Rotate the humidity control switch from low
to high to regulate the mist output.

5.

IMPORTANT:

When the unit runs out of water,

the transducer will automatically shut off.

6.

Turn the humidity control switch anti-clockwise
to the off (

) position, then unplug the unit.

7.

Before refilling the tank, empty any residual
water and follow the Daily maintenance
instructions.

8.

Refill the water tank with cool tap water and
replace onto the base.

9.

Plug power cord into the electrical outlet and
turn the humidity control switch clockwise to
the desired humidity level.

10. DO NOT move the humidifier with water in

the tank on the humidifier base. This may
cause the humidifier to function intermittently,
or stop emitting mist altogether. Should this
occur, simply remove excess water from the
humidifier base.

IMPORTANT:

If you do not plan to use your

humidifier for two or more days, make sure any
residual water is drained from the tank and base
to prevent any bacteria growth in stagnant water.

CARE AND CLEANING

Humidifiers provide comfort by adding moisture
to dry, heated indoor air. To get the most benefit
from the humidifier and to avoid product misuse,
follow all instructions carefully, specifically the
operation, care and maintenance guidelines.
Please note this is an electrical appliance and
requires attention when in use.
Cleaning your humidifier every one or two weeks,
depending on the water conditions is important in
order to maintain efficient, healthy, odour-free
operation. Water quality varies widely and,
combined with build-up of mineral scale in your
humidifier, may under certain conditions promote
the growth of micro-organisms in the water tank.

Before cleaning, Please note the
following:

• 

DO NOT use soap, detergents, abrasives,
gasoline, glass or furniture polish, or boiling
water to clean any part of your Ultrasonic
Humidifier. These will interfere with the
proper operation of your unit and may affect
its appearance.

• 

DO NOT use sharp or metal objects to clean
mineral deposits in the reservoir. Contact
with sharp objects can result in damage to
the plastic.

Mineral deposits should be soaked for up to
20 minutes in plain vinegar and water to
help with their removal.

DO NOT clean any part of your humidifier in
the dishwasher.

Daily maintenance:

1.

Before cleaning, set the humidity control
switch to the Off position (

) and unplug

the unit from the electrical outlet.

2.

Lift off the tank of the humidifier.

3.

Carry the base and the tank to the sink, then
drain and rinse the base and tank thoroughly
to remove any sediment or dirt. Wipe clean
and dry with a clean cloth or paper towel.

4.

Refill the tank with cool tap water as instructed
in “Operating Instructions”. Do not over fill.

5.

If moisture forms on walls or window, turn
the humidifier off.

3

2

TM

Fig. 1

B

D

E

A

F

G

C

Fig. 2

CONGRATULATIONS

By choosing a Bionaire

TM

humidifier, you have

chosen one of the finest humidifiers on the
market today.

READ AND RETAIN THE FOLLOWING
FOR FUTURE REFERENCE.

GENERAL DESCRIPTION 

(SEE FIG. 1/2)

A

Mist Output

B  Power On Light Indicator
C  Humidity Level Control Switch
D Base
E Water 

Tank

F Tank 

Carry 

Handle

G  Tank Lid To Fill With Water

IMPORTANT SAFEGUARDS

Please read this manual carefully before using
this appliance, as correct use will give you the
best possible performance.
When using electrical appliances, basic safety
precautions should always be followed, including
the following:

Read all instructions before using.

Close supervision is necessary
when any appliance is used near
children. Appliance must be kept
out of the reach of children.

Appliance must be used by a
responsible adult.

Unplug from outlet when not in use, before
putting on or taking off parts, and before
cleaning.

Do not operate any appliance with a damaged
cord or plug, or after the appliance
malfunctions or has been dropped or damaged
in any manner. If the cord is damaged, it must
be replaced by the manufacturer or a service
agent in order to avoid hazard.

The use of accessory attachments not
recommended or sold by Bionaire

TM

may

result in fire, electric shock or personal injury.

Do not use outdoors.

Do not let cord hang over edge of table or
counter, or touch hot surface including the
stove.

Do not use appliance for other than intended
use.

Always disconnect the appliance from the
supply if it is left unattended and before
assembling, disassembling or cleaning.

In the event of a momentary electrical
disturbance, the product may malfunction

and require user to reset the product.

Check the operating voltage shown on the
back of the unit. Do not operate at higher
voltage than shown.

Never turn on, plug in or unplug the
humidifier while your hands are wet in order
to avoid electric shock.

Ensure humidifier is level. If the humidifier is
not level always turn the power off before
handling it.

Do not disassemble the humidifier while it is
plugged in to avoid electric shocks.

If you need to replace the plug or cable
always refer to the instructions.

Do not operate appliance with a damaged
cord or if the appliance has been dropped or
damaged. To avoid the risk of electric shock
never disassemble the appliance. Take
appliance to a qualified repair centre for
examination and repair. Incorrect re-assembly
can cause a risk of electric shock when used.

If the power supply cord is damaged, it must
be replaced by the qualified persons in order
to avoid a hazard.

Do not place humidifier in front of ventilating 
outlets and keep away from furniture and
other electrical appliances.

Do not add water directly into the mist outlet.

Unplug the humidifier from the mains if it is
not to be used for any length of time.

Do not pour water into the mist outlet while
the humidifier is plugged into the mains.

When the water tank is full the humidifier
can be used for 8-10 hours without refilling.

NOTE:

Please note that the output level will

vary depending on the humidity and
temperature of the room.

Always place humidifier on a firm,
flat, level surface. A waterproof mat
or pad is recommended for under
the humidifier. NEVER place it on a
surface that may become damaged
by exposure to water and moisture
(i.e. finished floor).

DO NOT allow the Moisture Outlet to directly
face the wall. Moisture could cause damage,
particularly to wallpaper.

NEVER tilt, move, or attempt to empty unit
while it is operating. Shut off and unplug
before removing the water tank and moving
the unit. DO NOT attempt to remove the
water tank within 15 minutes after the
humidifier is turned off and unplugged.
Serious injury may result.

Excessive humidity in a room can cause water
condensation on windows and some furniture.
If this happens, turn the humidifier OFF.

U.K. and IRELAND

BU3000-I_07MLM2.qxd  12/11/07  15:22  Page 4

Summary of Contents for BU3000

Page 1: ...ne Customer Service Helpline 0800 052 3615 Holmes Products France 1015 Rue du Mar chal Juin Z I Vaux Le P nil 77000 Melun France Phone 33 1 64 10 45 80 Fax 33 1 64 10 02 32 FRANCE SERVICE CONSOMMATEUR...

Page 2: ...d rinse the base and tank thoroughly to remove any sediment or dirt Wipe clean and dry with a clean cloth or paper towel 4 Refill the tank with cool tap water as instructed in Operating Instructions D...

Page 3: ...r tout danger L utilisation d accessoires non recommand s ou non vendus par BionaireTM peut provoquer un incendie un choc lectrique ou des blessures N utilisez pas l appareil l ext rieur Ne laissez pa...

Page 4: ...on de contr le de l humidit C la position High Haut Apr s quelques minutes la sortie d air humide atteindra son volume maximal La vapeur ne 6 7 sera peut tre pas visible imm diatement avec le r glage...

Page 5: ...Bei Besch digungen des Netzkabels ist dieses von entsprechend qualifizierten Personen auszutauschen um Risiken zu vermeiden Stellen Sie den Luftbefeuchter nicht vor Luftaustritts ffnungen auf und hal...

Page 6: ...lang ohne Nachf llen betrieben werden HINWEIS Wie stark das Ger t die Luft befeuchtet h ngt ganz von der Luftfeuchtigkeit und Temperatur des Raumes ab Bei Besch digungen des Netzkabels ist dieses vom...

Page 7: ...n het vertrek 12 Verwenden Sie zur Entfernung mineralischer Ablagerungen im Wassertank KEINE spitzen scharfkantigen oder metallenen Gegenst nde Der Kontakt mit scharfkantigen Objekten kann zu Besch di...

Page 8: ...ers kraanwater 4 Plaats het deksel terug 5 Plaats de watertank E op de voet D 6 Zorg dat de luchtbevochtiger horizontaal staat Als de luchtbevochtiger niet horizontaal staat moet u hem altijd uitzette...

Page 9: ...tu 3 K ynnist ilmankostutin k nt m ll ilmankosteuden s t kytkin C asentoon suuri Laitteelta kest muutama minuutti saavuttaa suuri kosteusteho Huomaa ett alhaista asetusta k ytett ess h yry ei ehk ole...

Page 10: ...1 2 A Vanndamp B Indikator for str m p C Kontrollbryter for luftfuktighet D Sokkel E Vanntank F B reh ndtak for tank G Tanklokk som skal fylles med vann 18 NORSK 4 S d h yryn m r k nt m ll kosteuden s...

Page 11: ...kadet eller etter at apparatet har sviktet eller har blitt mistet i gulvet eller skadet p noen m te Hvis ledningen er skadet skal den skiftes ut av produsenten eller en servicerepresentant for unng en...

Page 12: ...t rst mulig utbytte av luftfukteren og unng misbruk av apparatet f lg alle anvisninger n ye spesielt retningslinjene for drift stell og vedlikehold V r oppmerksom p at dette er et elektrisk apparat so...

Page 13: ...vet i dette dokument Hvis det usandsynlige skulle ske i denne garantiperiode at apparatet ikke l ngere fungerer p grund af en design eller fabrikationsfejl bedes du returnere det til k bsstedet sammen...

Page 14: ...utar att fungera p r tt s tt eller har tappats eller den skadats p n got s tt Om n tsladden eller kontakten skadats m ste den bytas ut av tillverkaren eller dess auktoriserade reparat r f r att undvik...

Page 15: ...ra vattentanken E p basen D 6 Se till att luftfuktaren st r plant Om luftfuktaren inte st r plant ska du sl av str mmen innan du r ttar till den OBS Fyll inte p vatten direkt i basen D BRUKSANVISNING...

Page 16: ...Retire la tapa del dep sito y ll nelo con agua fresca del grifo 4 Vuelva a colocar la tapa 5 Coloque el dep sito de agua E sobre la base D 6 Aseg rese de que el humidificador est nivelado Si no lo es...

Page 17: ...do de manera espec fica las normas de funcionamiento cuidado y mantenimiento Tenga en cuenta que se trata de un aparato el ctrico y hay que vigilarlo cuando se utiliza Es importante limpiar el humidif...

Page 18: ...etergentes abrasivos gasolina polidores de vidro ou de m veis ou gua a ferver para limpar qualquer componente do humidificador ultra s nico Esses produtos poder o interferir com o funcionamento adequa...

Page 19: ...de concep o ou fabrico devolva o ao local da compra acompanhado do recibo e de uma c pia desta garantia Os direitos e benef cios adquiridos ao abrigo desta garantia complementam e n o afectam os seus...

Page 20: ...e Off ruotandolo in senso antiorario e scollegare il cavo dall unit 7 Prima di riempire di nuovo il serbatoio vuotare l acqua residua e svolgere le operazioni di manutenzione quotidiana 8 Riempire il...

Page 21: ...esclusi dalla presente garanzia Inoltre l uso normale compreso a titolo di esempio una lieve alterazione del colore sbiadimento e i graffi non sono coperti dalla presente garanzia I diritti spettante...

Page 22: ...42 15 55 1 C off 2 D E 3 4 5 E D 6 D 1 2 B 3 C 4 5 6 off 7 8 9 10 43 20 1 Off 2 3 4 5 1 2 3 2 Holmes Products Europe Ltd Holmes Holmes Holmes Holmes BU3000 I_07MLM2 qxd 12 11 07 15 22 Page 45...

Page 23: ...lyz kapcsol t az ramutat j r s val megegyez ir nyban A p ra rossz szag A g p j vagy a v z nem tiszta Nyissa fel a v ztart lyt s helyezze a k sz l ket h v s helyre 12 r ra Mossa ki a tankot vagy cser l...

Page 24: ...is illetve kell tapasztalattal vagy ismerettel nem rendelkez szem lyek nem haszn lhatj k a k sz l ket fel gyelet n lk l vagy an lk l hogy a k sz l k helyes haszn lat ra a biztons guk rt felel s szem...

Page 25: ...torem vlhkosti proti sm ru hodinov ch ru i ek do polohy Vyp a odpojte p stroj ze z suvky 7 P ed op tovn m napln n m n dr ky vypr zdn te ve kerou zbylou vodu a i te se pokyny v sekci Ka dodenn dr ba 8...

Page 26: ...KLADOV N Pokud nehodl te p stroj del dobu pou vat nap klad v letn ch m s c ch je t eba db t n sleduj c ch pokyn aby se v p stroji nezkazila voda 1 Vypn te p stroj a odpojte jej od p vodu elektrick ene...

Page 27: ...1 2 2 D 1 3 1 1 1 2 3 3 1 1 2 4 5 1 E 2 D 6 2 1 1 1 3 3 1 1 1 1 1 1 2 D 1 4 3 1 2 15 2 3 0 1 B 9 1 15 4 1 3 0 1 2 3 1 C 9 1 F 9 1 1 4 9 1 9 1 1 0 5 4 1 6 9 1 3 1 7 1 1 1 1 8 1 1 2 2 9 4 3 1 15 9 1 0 3...

Page 28: ...elektrycznym lub obra eniami cia a Nie nale y eksploatowa urz dzenia na wolnym powietrzu Przew d nie powinien zwisa ze sto u lub blatu ani dotyka gor cych powierzchni takich jak np piec Nie wolno u yw...

Page 29: ...eniem nale y zawsze wy czy zasilanie UWAGA Nie wlewa wody bezpo rednio na podstaw D INSTRUKCJA OBS UGI 1 Pod czy wtyczk do atwo dost pnego gniazda sieciowego 2 Po pod czeniu nawil acza do sieci elektr...

Page 30: ...warancji uzupe niaj prawa okre lone w przepisach na kt re niniejsza gwarancja nie ma wp ywu Zmiany niniejszych warunk w mo e dokona tylko firma Holmes Products Europe Ltd Holmes Firma Holmes zobowi zu...

Reviews: