BinTec elmeg T240 Operating Instructions Manual Download Page 53

Initial startup (telephone operation)

In stall  your  PABX  as  des cri bed  in  the  sec ti on  »In stal la ti on  ».

Make all ne ces sa ry con nec tions, in clu ding the 230 V AC mains po wer supp ly.

Note:
When you switch on the 230 VAC po wer supp ly you may not in ter rupt the supp ly of po wer du ring the in itia li za ti on
pha se of the PABX (20 se conds!)

In its in iti al sta te, the PABX will sig nal an ex ter nal call at the ana log ter mi nal de vi ces and at the ISDN ter mi nal de vi ce

that has the num ber.

You must then as sign the num bers (MSN and di rect dial-in) to the ter mi nal de vi ces via PC con fi gu ra ti on to en su re

that the ot her con nec ted te le pho nes and ter mi nal de vi ces can all be rea ched by ex ter nal par ties. 

If your PABX sys tem is set for use at a point-to-point con nec ti on it is cru ci al that you en ter your lo cal area code in the

Sec ti on »Dia ling re gi on« in PC Con fi gu ra ti on. Only af ter doing this can you take ad van ta ge of fea tu res such as »Call

for war ding«  (Parti al  Re rou ting)  and    »Au to ma tic  Call-back«.

Your PABX is equip ped with an in ter nal »Pho ne num ber plan« (see page 43) that can be edi ted. The in ter nal num -

bers (or MSN ex ten sions) have de fault set tings in the PABX’s in iti al sta te. You can chan ge the se in ter nal num bers as

you  re qui re  through  con fi gu ra ti on  with  the  PC. 

Your PABX supp orts the flash functi on for ana log te le pho nes. The re fo re, ne ver just brief ly re pla ce the hand set or

press the but ton in the crad le brief ly with your hand, as the PABX would take this as a flash sig nal ins te ad of han ging

up.

Configuration using a telephone
Con fi gu ra ti on  using  a  te le pho ne

Va ri ous set tings are pro tec ted by PIN1 in the PABX. In the de fault sta te, this PIN 1 is set to 0000. Af ter you be gin con -

fi gu ra ti on you can set the fea tu res for your sys tem using the codes des cri bed here. The te le pho ne being used for pro -

gram me ming can not be rea ched whi le the sys tem is being con fi gu red.

You  will  hear  the  po si ti ve  ac knowled ge ment  sig nal  once  you  suc cess ful ly  con clu de  con fi gu ra ti on  for  a  set ting.  You

can then move on to con fi gu re the next set ting. If you wait for more than 40 se conds bet ween one en try and anot her,

the PABX will ter mi na te con fi gu ra ti on and you will hear the busy sig nal. All in put made up to that point which was

con clu ded with a po si ti ve ac knowled ge ment sig nal will be sa ved when you hang up the hand set. Sa ving is per for med

for 10 se conds af ter you hang up the hand set. Du ring this pe ri od it is im por tant that you do not be gin a new con fi gu -

ra ti on of the sys tem, and that po wer is not in ter rup ted to the sys tem.

The  fol lo wing  pro ce du re  must  be  per for med  one  time  at  the  be gin ning  of  con fi gu ra ti on:

b

**

q

====

q

Lift up 

hand set

Ack. 

sig nal

En ter

PIN 1

Ack. 

sig nal

You can set the following features:

·

Set ting the date and the time (see page 47)

·

Can cel set tings (see page 47 )

·

En ab le  or  in hi bit  re mo te  ac cess  (see  page  47)

·

Char ge / Set ting up call ac counts (see page 18, 47)

Com mis sio ning  the  pho ne  part

45

Summary of Contents for elmeg T240

Page 1: ...Operating instructions English elmegT240...

Page 2: ...domesticwasteatanappropriatewastedisposalfacilityattheendof itsusefulservicelife Youwillfindadditionalinformationonanindividualreturningoftheoldappli ances under www bintec elmeg com bintec elmeg GmbH...

Page 3: ...one interlock 9 Making internal calls 9 Announcement 10 Making outside calls 10 Making outside calls at automatic exchange line access 11 Making external calls with prefix code 11 Trunk group routing...

Page 4: ...Least Cost Routing LCR 23 LCR Professional features 23 Activating the LCR procedure 24 Deactivating the LCR procedure 24 Block dialing Austria 24 PABX Settings 25 Activating and deactivating call sign...

Page 5: ...nstallation sequence 35 Connections to the PABX system 37 View inside the PABX system 37 PABX terminals 38 Assignment of the RJ12 jack 38 Modules 40 Module installation 40 Installation of the module e...

Page 6: ...hone 52 Download Manager 52 Configuration TAPI 52 LCR Professional 52 Application programs 53 Drivers 53 TAPI in the LAN 53 Initial installation 53 Installing the Programs from the CD ROM 54 Configura...

Page 7: ...tmapping 64 Information about data security when surfing the Internet 64 Dial in into the LAN RAS 64 Appendix 65 Troubleshooting 65 Technical specifications 67 Index 68 Brief description of functions...

Page 8: ...Table of contents VI...

Page 9: ...kept to a minimum Internet access for all of the PCs connected to the PABX system is provided via one single connection SUA single user account only one set of access data is required from your Intern...

Page 10: ...uchasstereoequipment electronicoffice equipmentormicrowaveunits AvoidinstallingyourPABXnearsourcesofexcessiveheat e g radiatorsorinroomswithexces sivehumidity Theambienttemperatureatthelocationwhereth...

Page 11: ...rough the POTS module Green flickering Two B channels busy B1 Showsthebusy statefortheexternalISDN connection Green lit The first B channel remains busy B1 Showsthebusy statefortheexternalISDN connect...

Page 12: ...d by the PABX Please repeat the operation All LEDs flashing New firmware being downloaded into the PABX Do not remove the plug in power supply unit for the PABX system during this phase as it can resu...

Page 13: ...issymbolindicatesthecallstatus a Replacethehandsetofyourphoneinthecarriage orthetelephoneisidle l Indicatessignalingataterminaldevice forexampleyourphonerings t Youcandialthedesirednumber 1x0 Dialaspe...

Page 14: ...ccepted Negative acknowledgement signal mixed tone 421Hz and 320 Hz ___ ___ ___ ___ ___ ___ ___ ___ ___ If you hear this tone the selected function can not be used or the feature has not been configur...

Page 15: ...recall with Clip ______________________ ____ _____________________ CLIP If your analog telephone has been configured for calling line identification CLIP it will be called with this signal External ca...

Page 16: ...n you make an external call You will hear the internal dial tone when you lift up your handset Note If your phone is set for Automatic line access you must first press the key when you lift the handse...

Page 17: ...nal party Conduct your call Making internal calls All phone calls fax transmissions or data transmissions that take place between internal analog devices are internal connections for which no charges...

Page 18: ...ese connections may also be to two different parties simultaneously For ex ample you can call an external business partner while simultaneously transferring data from your PC to a different businesspa...

Page 19: ...only use this performance feature when you are using more than one external port only with POTS modu le In the default setting the external ISDN port is used first after dialing the line access digit...

Page 20: ...wer If supported by your network provider you can use the function Completion of calls on no reply to reach the party immediately when he she endsacall orliftsandthenreplaceshis herhandset Yourtelepho...

Page 21: ...make a business call from home late at night you can define your business telephone number as the MSN for this business call TheadvantageisthattheconnectionanditscostarerecordedundertheselectedMSNand...

Page 22: ...andset Speed dialing from the telephone directory The PABX system is equipped with an integrated telephone directory in which you can make up to 500 entries each with up to a 24 digit number and up to...

Page 23: ...r more of your phones you need to lift the handset of one of these phones After five seconds without any numbers being dialed the PABX will automatically dial the defined direct call number Youcanente...

Page 24: ...x and must subsequently be enabled and configured once again Enabling room monitoring for an internal telephone b 593 q Lift up handset Ack signal Do not replace handset Do not deactivate hands free c...

Page 25: ...nded a call you will hear the busy signal from the ex change the caller s number is saved at the exchange Attention Only hang up the handset after you have entered the code for tracing the caller and...

Page 26: ...ess of their service function With exchange line acquisition using a codetheserviceIDsfor analogtelephony faxgroup3 or ISDNtelephony canbetransmitted regardlessofthe configuration for the analog conne...

Page 27: ...econds dependingonthesettingin thePABXorattheexchange partialrerouting Callforwardingonbusy Thecallisforwardedonlyifthedestinationtelephoneisbusy Note Ongoingcallforwardingcallsalsobeoverwrittenbyanew...

Page 28: ...gnal Replace handset Call will then be forwarded to the specified telephone Internal de activation of call forwarding Follow me internal and external b 64 t q a Lift up handset Internal number for whi...

Page 29: ...ing Follow me from an external location t q 64 t q a Enter PIN 2 Ack signal Internal number for which call forwarding is to be canceled Ack signal Replace handset After you cancel call forwarding posi...

Page 30: ...units Theseunitsarethenconvertedtoacurrencyvalueusingadefinedfactor Thecurrencymustbe specified previouslyinthePABXhowever Transferofthecurrencyvalue NoconversionrequiredinthePABX Ask your network pro...

Page 31: ...cesmust be applied for Some of these providers automatically set up a connection to enroll unregistered customers If you terminate such a connection during dialing and then subsequently attempt to set...

Page 32: ...ck signal Deactivating the LCR procedure b X q q 781 q Lift up handset Ack signal Enter PIN 0000 default setting Ack signal Code Ack signal Block dialing Austria Using block dialing prepared dialing y...

Page 33: ...figuration for the team for internal team calls IftheMSNisdialedbyanexternalparty ortheteamnumberbyaninternaluser alloftheassignedterminaldevices are called Different terminal devices can be assigned...

Page 34: ...you can assign two different call distribution options team call assignment day night to each team Call forwarding to an external subscriber is also possible for day night team call assignments allowi...

Page 35: ...riber underthetab Phonenumber Log inattheSMScenterandreceivingoftheSMSsarethenmadeusingthisnumber IfyouenteranSMS authorized telephoneintheteamcallallocation inthesection External numbers inseveraltea...

Page 36: ...erformed automatically at a time you specify Different day night changeo ver times can be selected for each day of the week A calendar consists of four switching times which in turn canbe specifically...

Page 37: ...table in the Section Restricted Numbers can not be dialed using theanalogterminaldevicesincludedintheassociateddialingregion Forexample theentryofthenumber 0190 in the list would prevent calls being...

Page 38: ...Youareconductingacall Youwouldliketocallanotherparty R PresstheRkey Youwillheartheinternaldialtone t Ifyouwishtospeaktoanexternalparty dial0first Ifyouhearabusysignalafterdialing0 eitheryourtelephone...

Page 39: ...willheartheinternaldialtone t Dialthenumberoftheinternalpartytowhomyouwishtotransferthecall Youwillheartheringingsignalinyourhandset Thepartywillbecalled IfyouhearthebusysignalpresstheRkeyagaintoretri...

Page 40: ...llwaiting R2 Dialthiscode Party2answers youcanspeakwithParty2Party1isputonhold R4 Youwouldliketoconnectthetwopartieswithoneanother Dialthiscode Thetwopartiesarethenconnected Thechargesfortheconnection...

Page 41: ...The feature Hold in PABX must be configured to conduct a three party conference call in the PABX with external or internal caller Both B channels of the ISDN connection are used when making a three p...

Page 42: ...the negative acknowledgement signal is heard the subscriber cancels the inquiry call and repeats the process for another internal extension released for the system parked inquiry During system parked...

Page 43: ...fficeequipment ormicrowave units AvoidinstallingyourPABXnearsourcesofexcessiveheat e g radiatorsorinroomswithexces sivehumidity Theambienttemperaturemustbebetween5and40 C Havingidentified theappropria...

Page 44: ...naldeviceconnectorsintothejacks IfyouwishtoconfigureyourPABXsystemyourselfviathePC youcandothisviatheUSBport onthePABX orattheinternalISDNconnection ToconfigurethesystemviathePCport connectthePABXsyst...

Page 45: ...a b7 a b8 a b8 1 1 2 2 NO NO S0 intern S0 intern S0 extern S0 extern a b1 a b1 2a b 2a b 1a b 1a b 3a b 3a b 4a b 4a b Modul Modul S0 intern S0 intern 2a b 2a b 1a b 1a b 3a b 3a b 4a b 4a b 5a b 5a...

Page 46: ...by PC configuration The PABX is equipped with two types of internal connections Fourconnectionsa b1 a b4forhard wiringofoutlets AfteryouhavepluggedaterminaldeviceintotheRJ12jackofthePABX youmaynotuse...

Page 47: ...ng on the type of USB connecting cord you are using The PABX system USB port is ready for operation at the PC connected to the system when the LED USB lights up andstayslit PCapplicationsthatrunviathe...

Page 48: ...ious modules can be used for the PABX systems You should first make a backup copy of all pabx data and then reset the system to default state code 999 Switch the system off then mount the modules Rest...

Page 49: ...nc 3 External connecting lead La 4 External connecting lead Lb 5 nc 6 nc Ports La and Lb are electrically isolated from the PABX system circuit Functional ground As the elmeg M 1 POTS module is equipp...

Page 50: ...a b 1 Fixing holes 2 Connector 3 Fixing holes ConnectiontothePABXsystemismadeusingtheribboncableprovidedwiththesystem Thetwoanalogsubscribers are connected at jacks a b5 and a b6 on the PABX system Mo...

Page 51: ...ethenumbers10 11and20areenteredandenabledforTeam00inthe day nightteamcallallocation Default setting TheexternalISDNconnectionissettopoint to multipointaccess Thefour digitPIN1 password issetto0000 The...

Page 52: ...n isactivated ThekeypadfunctionfortheexternalISDNconnectionisnotenabledforterminaldevices Themeterpulsefrequencyissetto16kHz Remoteaccesscanbeinitiated fromanyterminaldevice Remoteswitchingauthorizati...

Page 53: ...es Therefore never just briefly replace the handset or pressthebuttoninthecradlebrieflywithyourhand asthePABXwouldtakethisasaflashsignalinsteadofhanging up Configuration using a telephone Configuratio...

Page 54: ...teryouenterthis6 digitPIN2areyouallowedtoutilize functions in your PABX that can be activated deactivated from external telephones Note Remote access using this 6 digit PIN2 is only possible when this...

Page 55: ...you have the option of using the functions Callforwarding Followme Roommonitoring from an external location You can specify the required authorization for remote access to your PABX Enable inhibit the...

Page 56: ...one forexample atconnection1 internalnumber10 orfromate lephone at connection 2 internal number 11 You are connected with the service technician who then explains the further procedure to you When req...

Page 57: ...the data back into the PABX Note No further data links can be established when your PABX has been released for dial in by the service center If you wish to cancel enabling for remote access proceed as...

Page 58: ...port searchingforandconfigureyoursystemtelephones registerandeditcalldataonthePC editthephonedirectory LoadnewsystemsoftwareintothePABX surftheInternet sendandreceivedataintheEurofileformat requiresad...

Page 59: ...ance The provider the duration of the existing connection the port ISDN or DSL the external IP address assigned by the provider ifapplicable andthevolumeofthetransferreddataforuploadanddownload AnInte...

Page 60: ...system The current system software is available for downloading on the Internet at www bintec elmeg com Configuration TAPI Using TAPI Configuration you can adapt the TAPI driver for a program that use...

Page 61: ...B interface i e the PABX system Please note that software used for the CAPI application may require certain li censeagreementswiththesoftwaremanufacturer Theprogram CAPIinLAN doesnotrequirealicensetor...

Page 62: ...the Internet Before installing the new drivers be sure to remove any existing CAPI drivers in your system such as the drivers for an installed ISDN card as Windows only supports one installed CAPI Ref...

Page 63: ...gWind owsExplorer doubleclickonthefile orusingtheoption Run intheWindowsstartmenu When the file is started the welcome screen of the CD is displayed Configuration with a PC UsetheUSBconnectingcordsupp...

Page 64: ...henrestartyourPC AfterrestartingyourPCyouwillfindtheiconfortheControlCenterintheWindows Toolbar YoucansetuptheInternetconnectionviatheControlCenterandthenstartyourInternet browser Note If you already...

Page 65: ...Accessmethod Youwill thenseethe SetupWizard Under Selectaccessmethod specifyaccessviatherouter Under LAN selection mark Home LAN AfteryourPChasbeenrestartedyouwillseetheControlCentericonintheWindows T...

Page 66: ...re or can change the setting Initial Commissioning and Minimum Configuration Connection of a PC through USB installation Atpresent onlyMicrosoftWindowsoperatingsystemsaresupportedforconnectionofaPCtot...

Page 67: ...sedforthenamedefinitionforWindowsPCswhenyouuseaWINSserver in the LAN This parameter should only be configured when you operate a WINS server in the LAN Time Servers The parameter Time Servers is used...

Page 68: ...of the Internet Service providers ISP An Internet Service Provider provides you with an entrance portal to the Internet A distinction is made between ISPs with whom you have a contract for example T O...

Page 69: ...Terminateconnectionto provider Afterasettime whichcanbedefined duringwhichthereisnodatatraffictotheInternet the connection isterminated automatically Youcanactivate de activatethis function inthe conf...

Page 70: ...figuredbasedonourlatestknowledge Wecan however pro vide no guarantee for the function of the filters Use of a firewall should go hand in hand with use of virus scanning softwareonallyourPCs Firewallsa...

Page 71: ...llfiltersthataregeneratedwiththeFilterWizardarebasedonpacketsbeingdiscarded withtheex ception of those for which an appropriate rule exists The more filters you configure for the PABX system the more...

Page 72: ...rrespondingPCinyourLANistobeaccessiblefromtheInternet notpossibleinthestan dardconfigurationwithNAT Inthiscase certainUDPandTCPportsmustbereroutedtoaPCinthe LAN Information about data security when su...

Page 73: ...received Same causes and remedies possible as for No incoming internal calls PABX not connected cor rectly to the network termi nation unit of your network service provider Check the connection betwee...

Page 74: ...e In the system control panel folder System Device manager check whether the USB ports of your PC have been activated PABX drivers not properly loaded In the system control panel folder System Device...

Page 75: ...point connection ISDNcablelengthswith0 6mm Wirediameter Short passive bus max length of 120 meters Analog ports Supply PABX symmetrical 60 mA at 25 ohms Max lengthoftelephone connectioncableswhenusing...

Page 76: ...s Day and Night25 Busy tone 6 C Calendar 28 Call account 22 Call allocation 25 Call assignment 25 Call assignments 26 Call Control 29 Call data 51 Call data records 21 63 Call distribution 26 Call for...

Page 77: ...59 Domain Suffixes 59 Drivers on the CD ROM 53 54 E ECT Call switching 32 Emergency calls 29 Emergency numbers 28 Enable inhibit call waiting for a further call 11 Exchange authorization 10 External c...

Page 78: ...nal 9 Making outside calls with prefix code 11 Malicious call identification Tracing 17 Melody 44 Module elmeg M 1 POTS 41 Module elmeg M 2 a b 42 Module installation 40 Monitoring costs call account...

Page 79: ...ccess 47 51 Reset 47 for a subscriber s settings 48 for all settings and subscribers 48 Resetting settings to initial state 47 Resetting the PABX 47 Restricted numbers 29 Ringing signal 6 Room monitor...

Page 80: ...tions 52 Three party conference call 33 Time acceptance 29 Tone dialing 1 T Online number 56 Tracing Malicious call identification 17 Transfer in the exchange 32 within the PABX 32 Transfer calls 31 T...

Page 81: ...al call with prior notice gRta Forwarding an internal call without prior notice gRtg Inquiry call gRg Terminating a room inquiry with analog terminals gR4a Connecting external callers Broker s call gR...

Page 82: ...toring from internal terminals Inhibiting calls b 570qa Inhibiting internal and outside calls b 571qa Inhibiting outside calls b 572qa Inhibiting internal calls b 570qa Re enabling all calls Malicious...

Page 83: ...Declaration of conformity Declaration of conformity 75...

Page 84: ...S dwestpark 94 D 90449 N rnberg For information on support and service offerings please visit our Website at www bintec elmeg com where you will find a Service Support area Subject to modifications A...

Reviews: