Module installation
The mo du les have al rea dy been ta ken into ac count for the PABX sys tem. If a mo du le is in stal led pri or to in iti al com -
mis sio ning, the num bers are au to ma ti cal ly as sig ned to the con nec tions.
Va ri ous mo du les can be used for the PABX sys tems. You should first make a ba ckup copy of all pabx data and then
re set the sys tem to de fault sta te (code »999«). Switch the sys tem off, then mount the mo du les. Res tart the sys tem.
Note:
Dis con nect the PABX from all ana log, door ter mi nal and ISDN con nec tions. At ten ti on! You may be elec tro sta ti cal ly
char ged. To en su re that you have no elec tro sta tic char ge, touch a con duc ting ob ject con nec ted to»ground« (e. g. wa -
ter pipe) be fo re you open the PABX sys tem.
Plea se ob ser ve that only one mo du le can be in ser ted into each avai la ble PABX slot:
Slot 2 = Mo du le el meg M 1 POTS or mo du le el meg M 2 a/b.