CB (E7) 06/2018
Page 17/174
1.9
Measures to prevent accidents
The manufacturer took the following measures to prevent dangers:
•
Indications on the type plate
See operating manual chap. 1.4.
•
Operating manual
An operating manual is available for each chamber.
•
Overtemperature monitoring
The chamber is equipped with a temperature display, which can be read from outside.
The chamber is equipped with an additional safety controller (temperature safety device class 3.1 acc.
to DIN 12880:2007). Visual and audible (buzzer) signals indicate temperature exceeding.
•
Safety, measurement, and control equipment
The safety, measuring, and control equipment is easily accessible.
•
Electrostatic charge
The interior parts are grounded.
•
Non-ionizing radiation
Non-ionizing radiation is not intentionally produced, but released only for technical reasons by
electrical equipment (e.g. power cables). The machine is equipped with a permanent magnet located
behind the inner panel of the outer chamber door. If persons with active implants (e.g. pacemakers,
defibrillators) keep a safe distance (distance of field source to implant) of 30 cm, an influence of these
implants can be excluded with high probability.
•
Protection against touchable surfaces
Tested according to EN ISO 13732-1:2008.
•
Floors
See operating manual chap. 3.4 for correct installation
•
Cleaning
See operating manual chap. 21.