82
DSL service.
3
Reset your ADSL line to reinitialize your link to the DSLAM. For details, refer to the
Maintenance
chapter (web configurator) or the System Information and Diagnosis
chapter.
4
If these steps fail to correct the problem, contact your local distributor for assistance.
A.2 Console Port
I cannot access the BIPAC-5100/5100W via the console port.
STEPS
CORRECTIVE ACTION
1
Make sure the BIPAC-5100/5100W is connected to your computer's serial port.
2
Make sure the communications program is
configured correctly. The communications
software should be configured as follows:
VT100 terminal emulation.
9600 bps is the default speed on leaving
the factory. Try other speeds in case the
speed has been changed.
No parity, 8 data bits, 1 stop bit, data flow
set to none.
3
Make sure you entered the correct password. The default password is “admin”.
If you have forgot your username or password, refer to
Section A.5
.
A.3 Telnet
I cannot telnet into the BIPAC-5100/5100W.
STEPS
CORRECTIVE ACTION
1
Check the LAN port and the other Ethernet connections.
2
Make sure you are using the correct IP address of the BIPAC-5100/5100W. Check the
IP address of the BIPAC-5100/5100W.
3
Ping the BIPAC-5100/5100W from your computer.
If you cannot ping the BIPAC-5100/5100W, check the IP addresses of the
BIPAC-5100/5100W and your computer. Make sure your computer is set to get a
dynamic IP address; or if you want to use a static IP address on your computer, make
sure that it is on the same subnet as the BIPAC-5100/5100W.
4
Make sure you entered the correct password. The default password is “admin”.
If you have forgot your username or password, refer to
Section A.5
.
5
If these steps fail to correct the problem, contact the distributor.