Selecta: User Manual_______________
29
TOT2FLD.CFG = field list of total 2 weighing operations (download here a sample
file);
If the storage function is enabled but its respective configuration file is not present, or its
structure is not correct, at power up or when exiting configuration, an error window is
displayed.
Inside every file, there must be stored the process fields to be stored every
weighing operation
. Just one field must be placed on a line and the line must end with ";" (semi
column), but the last field of the list that must end with the character "|". Fields stored in the file
must match with the process fields listed in the network communication protocol. Only the
number of the process field must be entered, with no “L” at the beginning as in the case of the
network. If, for example, the LOT (L5) code is needed, just enter a new line with number 5
inside the file.