ELECTRIC PUMP
INCONVENIENT
AND
PROBABLE CAUSE
REMEDY
The
lifting
platform
during
the ascent and/or
descent vibrates
excessively
or
Air presence in the
Hydraulic
circuit
It is necessary to bleed the hydraulic
circuit by lifting and lowering the lifting
platform a few times.
The lift climbs
slowly and with
difficulty
Oil too viscous
If the air temperature falls below -6°/-
10° C, the oil decreases its fluidity. To
solve this problem, lift and lower the lift
a few times so that the oil increases its
temperature.
Operating on the
button panel, the
motor runs but
the lift does not
rise.
Oil level in the pump too
low.
Remove the casing of the pump and check
the oil level through the plug
(Figure 12). If
the level is too low, add ISO VG 10
hydraulic oil.
Hydraulic pump problems
Contact the dealer or Bike-Lift Europe s.r.l
Operating on the
button panel the
motor does not
run
The emergency stop (red
button in case of the built-
in lifting platform version)
on the button panel is
inserted
Release the red button on the button
panel by turning it clockwise.
No voltage
Check the mains connection plug
Improper operation of the
button unit on the button
panel
Replace the button unit
The motor is short-circuited
Contact the dealer or Bike-Lift Europe s.r.l
Summary of Contents for TWIN-ARMS MTA 516
Page 36: ...Operating manual No 057 2 6 0013 R0 Version 2018 Page 37 EN SPARE PARTS TECHNICAL DRAWINGS ...
Page 37: ...Operating manual No 057 2 6 0013 R0 Version 2018 Page 39 EN ...
Page 38: ...Operating manual No 057 2 6 0013 R0 Version 2018 Page 39 EN NOTES ...
Page 39: ...Operating manual No 057 2 6 0013 R0 Version 2018 Page 39 EN NOTES ...