Biegler BW 585 Instructions For Use Manual Download Page 2

IMPORTANT:

These instructions are an essential part of the device. They must therefore be
kept in a suitable place near the device and should accompany the device if it is
transferred to other users.

For proper and safe use of this device it is essential that the warnings and safety
instructions, as well as the instructions for use are read and carefully observed
by all users before first using the device.

It is the responsibility of those using the device to fully acquaint themselves with
its proper use and operation.

If a malfunction is suspected, the device is to be taken out of service
immediately and suitable warning signs should be attached to the device to
ensure that it cannot be used before necessary service and repair work has
been carried out.

BIEGLER

Instructions for use - BW 585

14 TECHNICAL DATA

Device:

Blood and infusion warmer

Type designation:

BW 585

Voltage:

230 V / 50-60 Hz  or  110 V / 50 Hz
check the voltage specified on the device label

Power consumption:

280 W

Type of protection 
against electric shock:

I

Degree of protection 
against electric shock:

B

Degree of protection 
against ingress of liquids:

IPX4

Safety protection:

230V:  primary 2 x 1.6 AT   secondary 315 mAT
110V:  primary 2 x 3.15 AT secondary 315 mAT

Temperature setting:

37°C - 41°C adjustable in steps of 0.5°C

High temperature cut-out:

42°C / 42.5°C / 45°C±3°C

Max. system pressure:

300 mmHg

Dimensions:

WxHxD  140 x 190 x 240 mm

Weight:

2.5 kg

Classification:

IIb according to rule 9

Type of operation:

continuous operation

15 MANUFACTURER

E. Biegler GmbH
Allhangstrasse 18a
A-3001 Mauerbach
Austria

Tel.  +43 1 979 21 05
Fax  +43 1 979 21 05 16

email: [email protected]
www.biegler.com

EN - Edition 03 / 2007

17

Summary of Contents for BW 585

Page 1: ...Instructions for use BW 585 Blood and Infusion Warmer 0123 EN Edition 03 2007...

Page 2: ...ork has been carried out BIEGLER Instructions for use BW 585 14 TECHNICAL DATA Device Blood and infusion warmer Type designation BW 585 Voltage 230 V 50 60 Hz or 110 V 50 Hz check the voltage specifie...

Page 3: ...C Values higher or lower than the ranges specified above may cause damage to the device or its accessories 16 EN Edition 03 2007 BIEGLER Instructions for use BW 585 Table of contents 1 Warnings and s...

Page 4: ...function deviating from the instructions for use do not use the device and return it to the service centre The periodic technical safety inspections must be carried out according to the section perio...

Page 5: ...ns Electromagnetic is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones an...

Page 6: ...w The customer or the user of the BW 585 should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic dis...

Page 7: ...ns for use before putting the system into operation 3 1 SETTING UP PROCEDURE Fix the BIEGLER BW 585 firmly to the infusion stand using the clamps at the back Diag 1 9 Only use infusion stands or poles...

Page 8: ...is switched off To reset the device or switch off the alarm the device must first be disconnected from the power supply Attention The temperature alarm can also be set off externally e g by exposure t...

Page 9: ...The manufacturer s warranty will be void if it is found that the maintenance disinfection and inspection instructions have not been followed according to the instructions for use the device was damag...

Page 10: ...all the alarms are active but the heating is switched off The BW 585 now slowly cools down When the temperature drops below the 36 5 C threshold the low temperature alarm should be active For reasons...

Reviews: