The heating is limited:
•
„---„ = no limitation, heating proceeds optimally
•
„po“ = by maximum device power
•
„ic“ = by maximum input current
•
„oc“
= by maximum inverter output current
•
„dut“ = by maximum inverter output voltage
•
„tE“
= by max. temperature
Errors
Shows a history of the latest errors that have occurred in the device. Turning the encoder clockwise
shows the full error history progressively.
8.6
Setting
Allows setting the heating parameters.
Press the encoder repeatedly until the
indicator lamp glows red
. Then turn the encoder to
select the parameter to display or set and press to confirm. The indicator lamp glows green
. Now
you can turn the encoder to set the desired parameter value. Press the encoder to confirm the setting;
this will return you to selection of another parameter, or select “---” to go to the next setting. To exit to
power settings immediately, press and hold down the encoder.
The display has the following states:
Indicator lamp
Status
red
parameter selection
green
value setting
The following parameters can be set:
Name
Display
Value
Return / exit
----
----
Heating mode
REG
CF = constant magnetic field / current
CP = constant heating power
Limiting input current
Ic.L
6.0 max. – 16.5A
= limit input current
Max. output power
Po.L
2.0 max. – 4.5kVA; Standard 4kVA
Cooling
CoL
Lo = silent mode (workshops, short-term capacit)
Std = standard mode
Hi = max. capacity / does not switch off
Water fill
FIL
No
Yes = activates filling and venting
Factory setting
FAC
No
Yes = factory setting
Unlock code
UnL
servicing menu code, to unlock features
Firmware
Fir
shows firmware version