8.4
Heating timer
The timer makes it possible to automatically stop heating after a set amount of time, enabling
accurate dosing of energy (heat) introduced to the material, e.g., for spot or repeated heating to a set
temperature.
Press the encoder repeatedly until the
TIMER indicator lamp glows red
. Turn to set the desired
heating time in seconds or deactivate the timer by selecting “OFF“.
If the timer is set, then the indicator lamp glows green
when the heating starts, and if the heating
is stopped by the timer, the indicator lamp starts flashing green
and the display shows the letters
“OFF” once the button is released. Releasing the button stops the heating immediately.
Note: If heating is started in the timer settings, the display will show the remaining heating time
(remaining heating time countdown).
Note: Press the encoder to enter pre-heating/program settings (see following chapter). To exit to
power settings immediately, press and hold down the encoder.
Indicator lamp
Status
red
heating time settings
green
timer active – heating in progress
green, flash
timer active – timeout
8.5
Info
Info enables display of basic information about the heating process and the device. It thus facilitates
selection or optimisation of induction coils for the material to be heated, removal of any problems, etc.
If you wish to display Info, press the encoder repeatedly until the indicator lamp
glows red
.
Turn the encoder to select the parameter to display and press to confirm. The display shows the latest
reading (indicator lamp glows green
),
or shows the current reading during the heating (indicator
lamp flashes green
).
Press again to return to parameter selection, and you can select another one. If you wish to exit the
Info display and continue to further settings, select “---” in the parameters and press to confirm. To
exit to power settings immediately, press and hold down the encoder.
Indicator lamp
Status
red
parameter selection
green, flash
latest reading
red, flash
current reading during the heating
The following parameters are available in Info
Description
Display
Value Unit
Return / exit
----
----
Power transmitted
P
0.01 kW
Output power
Po
0.01 kVA
Power factor
PF
1%
Frequency
FrE
0.1 kHz
Input current
OC
0.1A
Output current
IC
0.1A
Input voltage
VOL
Vrms
Cooling temperature
tEP
0.1°C
Limit
OL
--- = without limit
po = max. transmitted power
ic = max. input current
oc = max. output current
dut = max. duty inverter
tE = temperature
Error
Err
error history
Note: see annex for a list of errors.