Thank you for buying this product, our company is 

sure that you will be more than satisfied with the 

product’s performance. The product is supplied with 

a “

Warnings

” leaflet and an “

Instruction booklet

”. 

These should both be read carefully as they provide 

important  information  about  safety,  installation, 

operation and maintenance. This product complies 

with  the  recognised  technical  standards  and  sa-

fety regulations. We declare that this product is in 

conformity with the following European Directives: 

2004/108/EEC  and  73/23/EEC  (and  subsequent 

amendments).

GENERAL SAFETY

WARNING! An incorrect installation or improper 

use of the product can cause damage to persons, 

animals or things. 

•  Scrap packing materials (plastic, cardboard, po

-

lystyrene etc) according to the provisions set out 

by current standards. Keep nylon or polystyrene 

bags out of children’s reach.

•  Keep the instructions together with the technical 

brochure for future reference.

•  This product was exclusively designed and ma

-

nufactured for the use specified in the present 

documentation. Any other use not specified in 

this documentation could damage the product 

and be dangerous.

•  The Company declines all responsibility for any 

consequences  resulting  from  improper  use  of 

the product, or use which is different from that 

expected and specified in the present documen

-

tation.

•  Do not install the product in explosive atmosphere.

•  Disconnect  the  electrical  power  supply  before 

carrying out any work on the installation. Also 

disconnect any buffer batteries, if fitted.

•  Only use original parts for any maintenance or 

repair operation.

•  Instruct the product user about the control systems 

provided and the manual opening operation in 

case of emergency.

•  Do not allow persons or children to remain in the 

automation operation area.

•  Keep radio control or other control devices out of 

children’s reach, in order to avoid unintentional 

automation activation.

•  The user must avoid any attempt to carry out work 

or repair on the automation system, and always 

request the assistance of qualified personnel.

•  Anything which is not expressly provided for in 

the present instructions, is not allowed.

•   Fit an omnipolar or magnetothermal switch on the 

mains  power  supply,  having  a  contact  opening 

distance equal to or greater than 3,5 mm.

•   Check  that  a  differential  switch  with  a  0.03A 

threshold is fitted just before the power supply 

mains.

•   The power supply must have a very low safety 

voltage  and  the  generator  must  be  protected 

against short circuit.

1) GENERAL OUTLINE

Programmable digital pushbutton panel for control

-

ling pedestrian and vehicle access points using two 

operating methods: 

1 - Serial connection:

  Manages  control  panels  provided  with  serial 

connection.

  Up to 16 different codes can be memorised. Each 

valid code sends a start command through the 

serial line. 

2 - Interfaced with a Compass system:

  The pushbutton panel is integrated in the Com

-

pass access control system. 

Provided with an anti-break-in metal container, 

the Seletto pushbutton panel does not directly 

control access point opening. Therefore, it can 

also be safely installed in unprotected areas.
2)TECHNICAL SPECIFICATIONS

Power supply:

 ................12/24 V

~

/   ±10% 50Hz

Absorption:

 ..................................................

60 mA

Working temperature:

 ......................... -10 / +55°C

No. codes (serial connection):

 ...........................

16

Dimensions: ............................................

see fig. 1

Degree of protection: .....................................

IP 44

3) INSTALLATION

Various types of mounting are possible:

3.1) Recessed mounting on wall (SELETTO)

Make a hole where the supplied plastic container is 

to be inserted, this will be held in place by concrete 

filling (Fig. 1a).

3 fixing clips are supplied (Fig. 1a “G”) to be scre

-

wed on the container before carrying out concrete 

filling.  

After the concrete has set, the 3 screws must be 

removed to allow the gasket and metal ring nut to 

be subsequently fitted.  

3.2)  Recessed  mounting  on  metal  pillar  (SE-

LETTO)

Make a hole by means of a ø 60 milling cutter where 

the supplied plastic container is to be inserted. To 

fix the container, drill three ø 3.6 holes for the three 

self-tapping screws. 

3.3) External container mounting (SELETTO E)

Use the box as a drilling template and drill 4 holes. 

Fix by means of self-tapping screws or expansion 

plugs, depending on the surface the box is being 

fixed

 on. Use the black sponge (H) between the 

appliance and the wall (Fig.1b).

Summary of Contents for SELETTO

Page 1: ...ROGRAMMABLE DIGITAL PUSHBUTTON PANEL CLAVIER NUMERIQUE PROGRAMMABLE PROGRAMMIERBARE DIGITALKNOPFTAFEL BOTONERA DIGITAL PROGRAMABLE BOTOEIRA DIGITAL PROGRAM VEL ATTENZIONE Leggere attentamente le Avver...

Page 2: ...2 SELETTO Ver 05 D811409_05...

Page 3: ...quello che non espressamente previsto in queste istruzioni non permesso Prevedere sulla rete di alimentazione dell auto mazione un interruttore o un magnetotermico onnipolare con distanza di apertura...

Page 4: ...2 solo per funzionamento seriale ON Funzionamentonormale attesadiimmissione codice OFF Attiva la modalit di programmazione dei codici JP2 Selezione alimentazione a 12V o 24 V JP2 aperto Alimentazione...

Page 5: ...zioni del quadro comando per ulteriori informazioni SeguendoloschemadiFig 3 procederealcablaggio dellalineaserialedeiquadricomandocontrollatidalla pulsantiera SELETTO utilizzando esclusivamente un dop...

Page 6: ...dici non validi il segnalatore acustico emette il segnale di errore per 60s tempo durante il quale non possibileeffettuarealtritentatividiaccesso Ogni ulteriorecodiceerratocomportaaltresegnalazio ni d...

Page 7: ...always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed Fit an omnipolar or magnetothermal switch on the mains pow...

Page 8: ...TX1 TX2 DIP 2 only for serial operation ON Normal operation wait for code entry OFF Activates the code programming mode JP2 Power supply selection at 12V or 24 V JP2 open Power supply 24V Fig 3 JP2 c...

Page 9: ...o wire the serial line of the control panels managed by the SELETTO pushbutton panel exclusively using a telephone type line In the case where a telephone cable has several pairs of wires it is indisp...

Page 10: ...r sound for 60s during which time no other attempts at access can be made Any further incorrect code causes othererrorsignalstobeemitted withconsequent waiting time 4 Record the code numbers entered e...

Page 11: ...e d action de la motorisation Nepaslaisserdesradiocommandesoud autres dispositifs de commande port e des enfants afin d viter des actionnements involontaires de la motorisation L utilisateur doit vite...

Page 12: ...24 V 2 0 V 3 4 Sorties rielleverslescentralesdecommande 3 TX1 4 TX2 5 6 Sortie donn es pour la connexion Com pass 5 D 6 D1 5 INTERRUPTEURS DIP DIP 1 ON Connect au syst me COMPASS Le code est transmis...

Page 13: ...m me code L alimentation 24V peut tre prise des sorties 24V Alimentation des acces soires de la centrale de commande V rifier la puissance maxi absorb e par les dispositifs connect s L introduction d...

Page 14: ...la fin de la programmation reporter DIP2 sur ON 8 AVERTISSEMENTS 1 Une attente de plus de 10 s entre la composition d un chiffre et la suivante annule l introductions et doit donc tre r p t e 2 l aver...

Page 15: ...Kindern liegenlassen Sie k nnten die Anlage versehen tlich in Gang setzen Der Betreiber hat jeden Versuch eines Ein griffes oder der Reparatur zu unterlassen Nur entsprechendqualifizierteFachleutesind...

Page 16: ...Eingabe eines g ltigen Codes der im inter nen Speicher der Knopftafel abgelegt ist wird ein Startsignal ber den seriellen Ausgang TX1 TX2 geschickt DIP 2 nur f r seriellen Betrieb ON Normalbetrieb Co...

Page 17: ...elche Betriebslogik auf der Steu erplatine vorgegeben ist 2 3 4 Schritte verh lt sich die Anlage unterschiedlich Weitere Informationen entnehmen Sie bitte der Betriebsanleitung der Steuerplatine Nach...

Page 18: ...er langgezogener Ton Eingabe Enter 0 8 durchgehender kurzer Ton Fehler ung ltige Funktion 3 Werden nacheinander 5 ung ltige Codes einge geben ert nt ein Fehlersignal von 60s L nge W hrenddessen sind w...

Page 19: ...itivos de mando al alcance de los ni os para evitar el accionamiento involuntario del automatismo El usuario debe evitar cualquier intento de intervenci n o reparaci n del automatismo y dirigirse nica...

Page 20: ...P1 1 2 Entrada alimentaci n 12 24 V 10 50 Hz 1 12 24 V 2 0 V 3 4 Salida serial hacia los cuadros de man dos 3 TX 4 TX2 5 6 Salida datos para la conexi n a Com pass 5 D 6 D1 5 DIP SWITCHES DIP 1 ON Con...

Page 21: ...V Alimentaci n ac cesorios del cuadro de mandos Es necesario controlarlaabsorci nm ximadelosdispositivos conectados La introducci n de un c digo v lido comporta el env o de una orden de START en la l...

Page 22: ...sucesiva pone a cero la intro ducci n que por tanto debe repetirse 2 El indicador ac stico puede emitir 3 tipos de se alizaci n sonido breve nico introducci n num rica sonido largo introducci n Intro...

Page 23: ...tiza o N o deixe radiocomandos ou outros dispositi vos de comando ao alcance de crian as para evitar accionamentos involunt rios da automa tiza o O utilizador deve evitar qualquer tentativa de interve...

Page 24: ...uadros de comando 3 TX1 4 TX2 5 6 Sa da dados para conex o a Compass 5 D 6 D1 5 DIP SWITCH DIP 1 ON Conectado a sistema COMPASS O c digo transmitido por meio das sa das 5 6 a um sistema COMPASS para a...

Page 25: ...enta o acess rios do quadro de comando Verificar a absor o m xima dos dispositivos conectados A introdu o de um c digo v lido comporta o envio de um comando de START para a linha serial Ulteriores int...

Page 26: ...NCIAS 1 Uma espera de mais de 10 s entre a digita o de um d gito a o seguinte zera a introdu o que portanto deve ser repetida 2 O sinalizador ac stico pode emitir 3 tipos de sinaliza o som breve nico...

Page 27: ...SELETTO Ver 05 27 D811409_05 H G...

Page 28: ...28 SELETTO Ver 05 D811409_05...

Page 29: ...05 29 D811409_05 Fig 3 24V 24V SELETTO in un sistema seriale SELETTO in a serial system SELETTO dans un syst me s riel SELETTO in einem seriellen system SELETTO en un sistema serial SELETTO em um sis...

Page 30: ...30 SELETTO Ver 05 D811409_05 AWG 0 35 mm SELETTO COMPASS 485...

Page 31: ...peisen kann La alimentaci n de 12V puede obtenerse de las salidas 14 17 del Compass SC que puede alimentar hasta 2 botoneras Seletto A alimentaci n 12V pode ser obtida nas sa das 14 17 do Compass SC q...

Page 32: ...URAN A Urbaniza ao da Pedrulha Lote 9 Apartado 8123 3020 305 COIMBRA PORTUGAL tel 351 239 082 790 fax 351 239 082 799 e mail geral bftportugal com BFT S P A Via Lago di Vico 44 36015 Schio Vi Italy te...

Reviews: