- 38 -
Control unit
EN
ENGLISH
RECOMMENDED DIMENSIONS
This solution is recommended when you want to allow entry to a reserved area, without using any commands, allowing transit of vehicles in
just one direction.
The vehicle approaches the
reserved area. When over the
loop
S1
, the bollard goes down.
When the vehicle is no longer
over loop
S2,
the bollard will
rise again.
Loops S1 and S2 also have a safety function in that they will not let the bollard to move all the time if the vehicle is over S1 or S2.
13.2
INSTALLATION B
AUTOMATIC ENTRY OR EXIT
ONE DIRECTION
ONE DIRECTION
ONE DIRECTION
PARAMETER
DATA
DESCRIPTION
35
=
&/
The close command acts as a close-when-released and safety function.
5
Radio channel 1: Disabled
)S
Opening consent
/2
Semiautomatic logic
&3
Command during pause is OFF
- Connect the
N.O.
contact of the coil receiver
S1
to the
OPEN
input.
- Connect the
N.O.
contact of the
S2
loop receiver to the
CLOSE
input.
- The dimensional values given are only approximate.
We suggest installing the “
RME 2
” metal mass detector.
*
Summary of Contents for PERSEO-CBE