- 40 -
Control unit
EN
ENGLISH
This solution is recommended when you want to enter a reserved area in both directions. Entry is by means of a command while exiting is
automatic.
EXIT
When the vehicle leaves loop
S2
the
bollard will rise automatically after an
adjustable pause time.
The vehicle approaches the reserved
area, when it is over the loop
S2
, the
bollard goes down.
When the vehicle leaves
loop
S1
the device will
rise automatically after
an adjustable pause time.
RECOMMENDED
DIMENSIONS
Loops S1 and S2 also have a safety function in that they will not let the bollard to move all the time if the vehicle is over S1 or S2.
ENTRY
When the vehicle is over loop
S1
the
bollard will go down only after a com-
mand (ex.: remote control).
If the device is rising and the user
wants to lower it again, the vehicle
must be over loop
S1
and the com-
mand must be repeated.
The vehicle approaches
the reserved area.
13.4
INSTALLATION D
CONTROLLED ENTRY AND AUTOMATIC EXIT
PARAMETER
DATA
DESCRIPTION
35
=
/R
Functioning logic: Automatic
)S
Special function
5
Radio channel 1: Open
&3
Command during pause is OFF
&/
Close standard
- Connect the contact of loop
S1
receiver to
PDM
input.
- Connect the N.O. contact of the
S2
loop receiver to
OPEN
input.
- The dimensional values given are approximate.
We suggest installing the “
RME 2
” metal mass detector.
*