- 37 -
Control unit
EN
ENGLISH
RECOMMENDED DIMENSIONS
This solution is recommended when you want to enter a reserved area in just one direction, by activating a command (radio control, proximity
key, magnetic keys, etc.).
The vehicle approaches the
reserved area.
When the vehicle is on the loop
S1
the bollard will go down only after
a command (ex.: remote control).
If the bollard is closing and the
user wants to lower it again, the
vehicle must be over loop
S1
and
the command must be repeated.
When the vehicle is no longer
over loop
S2
the bollard will
close.
Loops S1 and S2 also have a safety function in that they will not let the bollard to move all the time if the vehicle is over S1 or S2.
ONE DIRECTION
ONE DIRECTION
ONE DIRECTION
ONE DIRECTION
13. EXAMPLES OF CONTROLLED ENTRIES/EXITS
13.1
INSTALLATION A
CONTROLLED ENTRY OR EXIT
PARAMETER
DATA
DESCRIPTION
35
=
&/
The close command acts as a close-when-release and safety function.
5
Radio channel 1: Open
)S
Opening consent
/2
Semiautomatic logic
&3
Commands during pause is OFF
- Connect the
N.O.
contact of the
S1
loop receiver to
PDM
input.
- Connect the
N.O.
contact of the
S2
loop receiver to
CLOSE
input.
- The dimensional values given are approximate.
We suggest installing the “
RME 2
” metal mass loop detector.
*
Summary of Contents for PERSEO-CBE