- 30 -
Control unit
EN
ENGLISH
8.2
1st LEVEL
PROGRAMMING
The following table gives the 1st level functions and the adjustable parameters.
= DEFAULT value set in factory.
= parameter value set during installation: should be fi lled if
DEFAULT value is modifi ed.
Description of level 1 parameters
·
/R
: Functioning logic
- Hold-to-run: Close function active for as long as inputs are active. Open function activated by activating and releasing input. The
start command opens once and closes once.
- Semi automatic: The automation works with jog commands, without automatic reclosing. Hence, when fully open, to control closing
you need to act on the start or close command respectively.
- Automatic: The automation works in jogs. When the opening manoeuvre is completed in the standard cycle, automatic reclosing is
activated after the pause time set (parameter
W3
).
Par
Function
Settable data
/R
Selects the functioning logic.
(see notes after the table)
: Hold-to-run
: Semi automatic
: Automatic
&/
Close input confi guration (see
notes after the table)
: Standard close input
: Close-when-released input
: The close command acts as a close-when-released and safety function.
)W
Photocells
: During, it reopens and waits for the photo cell free commands closing.
: When closing it reopens; closes after 1’’ when the photocell is free
: When closing it reopens; closes after 5’’ when the photocell is free
2E
Obstacle detection
(for hydraulic bollards only)
: Disabled
: When closing it stops and waits for commands
: When closing it reopens and waits for commands
: When closing it reopens, then closes after 5 seconds
S2
Opening-warning time
S&
Closing-warning time
/'
Bollard lights
: Cover lights fl ashing during movement, fi xed on when the bollard is
opened and closed
: Cover lights fl ashing during movement and with bollard open, fi xed on
when the bollard is closed
: Cover lights always fl ashing
: Cover lights fl ashing during movement and with bollard closed, fi xed
on when the bollard is open
W3
Pause time (in seconds)
-
%X
Buzzer
: Buzzer off
: Buzzer on during movement
3U
Preset controlling entrance
confi guration
: none
: Confi guration of installation type A parameter (see chapter 13.1)
: Confi guration of installation type B parameter (see chapter 13.2)
: Confi guration of installation type C parameter (see chapter 13.3)
: Confi guration of installation type D parameter (see chapter 13.4)
G)
Resetting default parameters.
(see notes after the table)
: No resetting
: Resetting the default parameters
: Same as
, except for “COM” parameters that are not reset
67
Exiting the menu/saving
Pressing the “F” key exits the programming menu and changes are saved