- 31 -
Control unit
EN
ENGLISH
8.3
2nd LEVEL
PROGRAMMING
The following table gives the 2nd level functions and the adjustable parameters.
= DEFAULT value set in factory.
·
&/
: Close confi guration
-
:
Close-when-released input
The bollard closes automatically only when the vehicle has completely passed by the photocell or magnetic detector (the recom-
mended accessories for this purpose). Connect the N.O. contact of the detector or photocell to the close input terminals.
If the vehicle is on the detector or in front of the photocell it does not cause immediate closing but the control board will wait for
the signal to be released (i.e. vehicle moved).
-
: The close command acts as close-when-released and safety function.
When closing, a close command stops the automation. When close input becomes inactive the bollard resumes closing.
·
3U
: Preset
- To confi gure the parameters for installation type
A
,
B
, C and
D
; set the corresponding value and exit the menu. See chapter 13 for
details on installation types.
·
G)
:
Default
- To restore the parameters to the factory default values, set the “DF” to 1 or 2, then exit the menu. if
3)
=
the communication
“Com” settings is are kept.
Warning: The “default” operation sets all parameters to the factory default values, including the Preset values and the bollard type.
= parameter value set during installation: should be fi lled if DE-
FAULT value is modifi ed.
Par
Function
Settable data
6U
Request for maintenance
: disabled
: active on the confi gured outputs
: as in
plus lights fl ash twice
1W
Programming maintenance
cycles in thousands
1/
Programming maintenance
cycles in millions
.
.
.
R
R
Output 4, Output 5
: scheduled maintenance required
R R
: photocell triggering
: obstacle detection (for hydraulic bollard only)
: PDM input active
: bollard fully up (close position)
: bollard fully down (open position)
: STOP input active
: warning fl ash
: START input active
: OPEN input active
: power failure (the output is activated at switch-on)
: assistance required
: CLOSE input active
: UPS
: second radio channel active
: buzzer (for Totem)
)&
Closing limit switch presence
: not present
see
note
: present
HI
ECD present (for SD version
and XPASS B 1200C)
: not present
: present
7H
TERMON
: heating level (
= min;
= max)
XS
UPS
: disabled
: enabled, opens automatically during mains failure
: enabled, closes automatically during mains failure
WARNING:THIS SELECTION MAY BE DANGEROUS