TABLE “C” - LEVEL 3° PROGRAMMING
Parameter
Definition
Default
Cross Out
Setting Used
Optional Extras
Description
PD
PDM dynamic
input polarity
00
00
Input configured as NO
01
Input configured as NC
Pa
Output AUX
polarity
00
00
Output configured as NO
The outputs can be configured as NO or NC, but in
the event of a power outage, the contacts will open
anyway
01
Output configured as NC
CP
Commands
during pause
01
00
OFF
Depending on how the parameter is set, the automa-
ted device accepts or rejects commands during pause
time..
01
ON
FP
Special PDM
functions
00
00
None
Not configured.
01
Opening consent
PDM is used to enable opening. Until it is pressed, no
opening command is accepted through the OPEN
input. If PDM is held down, no closing command is
accepted through the CLOSE input, meaning the
bollard stays open.
02
Opening consent and pause time reset
The PDM functions as described in point 1, but in case
of automatic logic, the pause time is reloaded.
03
TERMON enabling
The PDM function enables the TERMON system. Based
on the setting of the PD parameter, the closing or
opening of the contact activates or deactivates the
TERMON system. This makes it possible to interface a
schedule with a potential free contact to optimise the
heating system.
R1
Radio chan-
nel 1
command
selection
01
00
Channel 1 deactivated
01
Channel 1 set as START
02
Channel 1 set as OPEN
HT
Select mains
frequency
30
20-80
INSTALLATION MANUAL