PERSEO CBD 230.P SD -
15
D811944_04
1) GENERAL INFORMATION
The PERSEO CBD 230.P SD control board comes with standard factory settings.
Any change must be made using the programmer with built-in display.
Fully supports EELINK protocol.
Its main features are:
Control of up to 4 bollards: STOPPY MBB -500 C. - STOPPY MBB 219-700 C.
Note: Bollards of the same type must be used.
- Separate inputs for safety devices
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance or
replacement easier. It comes with a series of prewired jumpers to make the installer’s
job on site easier. If the terminals are being used, remove the relevant jumpers.
2)
TECHNICAL SPECIFICATIONS
Power supply*
220-230V 50-60Hz (*)
Motor outpu
220-230V~; 3A max
Flashing light/traffic light
220-230V~; 40W
Accessory output:
24V~; 1A max
LED Output
24V~ 0,1A max
Buzzer Output
24V~ 0,1A max
Aux Contact
Max 24V 0,5A
2nd Ch rx Contact
Max 24V 0,5A
Low voltage/mains insulation
>2Mohm 500Vdc
Operating temperature range
-20° C+ 60° C
Thermal overload
protection built into motor
Dielectric rigidity
mains/LV 2500Vac for 1 second
Dimensions
See Fig.B
Fuses
See Fig.C
3) RECEIVER TECHNICAL SPECIFICATIONS
Max. n° of radio transmitters that
can be memorized
2048
INSTALLATION MANUAL
Frequency
433.92 MHz
Code by means of
Rolling-code algorithm
N° of combinations
4 billion
RADIO CHANNEL FUNCTIONALITY
PR1
Select the command from parameter
R1
PR 2
Closes the relay contact on the terminal
block J4 “2nd CH RX”
(* other voltages to order)
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
3) TUBE ARRANGEMENT Fig. A
4) CONTROL PANEL DIMENSIONS Fig.B
5) TERMINAL BOARD WIRING Fig. C
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
WARNING! For connection to the mains power supply, use a multicore
cable with a cross-sectional area of at least 3x1.5mm2 of the kind provided
for by the regulations in force.
To connect the motors, use a cable with a cross-sectional area of at least 1.5mm2
of the kind provided for by the regulations in force. By way of example, if the
cable is run outside (unprotected), it must be at least type H07RN-F, while if it is
run inside (in a raceway), it must be at least type H05 VV-F.
POWER TERMINAL BLOCK J2
Terminal
Description
Single-phase power supply
220-230V 50/60Hz
, with earth cable
L Live
N Neutral
E Earth
MOTA
COM
MOTB
M
Motor connection
MOTA Motor opening
COM Motor Common
MOTB Motor closing
CAP
CAP
Motor capacitor
EV
EV
Not used
SL
GR
RD
SL Flashing Light - max. 40W
SL-COM/ gR-RD-COM 230V
gR green Light - max. 40W
RD Red Light - max. 40W
L N E
SL-COM GR-RD-COM
ENGLISH