18 -
PERSEO CBD 230.P SD
D811944_04
INSTALLATION MANUAL
Parameter
Definition
Default
Cross Out
Setting Used
Optional Extras
Description
Lo
Selects the
functioning
logic.
01
00
Hold-to-run
The automation works when the commands are held
down. The start command opens once and closes once.
01
Semi automatic
The automation works with jog commands, without
automatic reclosing. Hence, when fully open, to control
closing you need to act on the start or close command
respectively.
02
Automatic
The automation works in jogs.When the opening
manoeuvre is completed in the standard cycle, auto-
matic reclosing is activated after the pause time set
(parameter tP).
CL
Close input
configuration
00
00
Standard close input
The command causes the device to close
01
Close-when-released input
Close-when-released input
This mode has been developed so the bollard closes
automatically only when the vehicle has completely
passed by the photocell or magnetic detector (the
most suitable accessories for this purpose). Connect
the NO contact of the detector or photocell to the
Close contact terminals.
If the vehicle is on the detector or in front of the photo-
cell it does not cause immediate closing but rather you
have to wait for the signal to be released.
02
The close command acts as a release closing and safety
function.
The close command acts as a release closing and safety
function.
When closing, the close command engaging stops the
automation. When disengaged the bollard resumes
closing.
Ft
Photocells
02
00
During closure, it reopens and waits for the photoelectric
cell free commands.
01
When closing it reopens; reclosing after 1’’ when the photo-
cell is disengaged
02
When closing it reopens; reclosing after 5’’ when the photo-
cell is disengaged
OB
Not available
03
00
Not available
01
02
03
PF
Warning flash
00
0-30
Before each start, the flashing light is activated, for the
set time, along with the AUX output, if set (
AU
parame-
ter). A 0 pre-flashing is disabled.
LD
Bollard lights
00
00
Cover lights flashing during movement, cover lights fixed
when the bollard is opened and closed
01
Cover lights flashing during movement and with bollard
open, cover lights fixed when the bollard is closed
02
Cover lights always flashing
03
Cover lights flashing during movement and with bollard
closed, cover lights fixed when the bollard is open
Bu
Buzzer
01
00
Buzzer off
01
Buzzer on during movement
dF
Resetting
default para-
meters.
00
00
No resetting
To reset the default parameters, set parameter
dF
on 1
and exit the menu’.
01
Resetting the default parameters.
02
Not available
03
04
05
tP
Pause time
(expressed in
seconds)
10
1-99
Waiting time before automatic closing in Automatic
mode (
Lo
parameter).
TABLE “A” - LEVEL 1° PROGRAMMING