16 -
PERSEO CBD 230.P SD
D811944_04
POWER TERMINAL BLOCK J5
Terminal
Description
24 Vac
OUT24
Output 24V~, 1A MAX
24 V
ac
LED
LED (Cover lights)
Self-powered output. 24V~, 100mA max
BZ
BZ
BZ (Cover buzzer)
Self-powered output. 24V, 100mA max
AU
X
AU
X
AUX
Free contact relay output; 500mA max, 24V / Vdc
2nd
CH
RX
2nd CH RX
Built-in radio receiver 2nd channel N.O. output, max. 500mA, 24 Vac/Vdc
INPUTS TERMINAL BLOCK J9
Terminal
Description
ST
ART
COM
START
N.O. input that operates the bollard’s opening and closing. The command is ignored while opening.
PDM
COM
PDM
Programmable input. Use parameters
FP, PD
and
AU
for the setting procedure.
OPEN
COM
OPEN
N.O. input - opening only Connect clocks, daily timers or weekly timers here if wanted.
By keeping this input controlled, the automation performs the opening manoeuvre and will close automatically only
when the input is freed.
CL
OSE
COM
CLOSE
N.O. input for closing. It allows the automation to be closed only if the safety devices have not triggered.
FTC
COM
FTC
NC safety input (photocell). Enter the programme wanted by programming the
FT
parameter. It triggers only in the
closing phase; it never triggers in opening.
ST
OP
COM
STOP
N.C. safety input. When it is activated, the automation is immediately stopped. During the pause time, a stop control
eliminates the automatic closing, leaving the bollard open waiting for a command.
FC
A
COM
FCA
Opening limit switch N.O. input. . When activated the opening travel finishes.
FCC
COM
Not used
INPUTS TERMINAL BLOCK
J10
.
Terminal
Description
EF
EF Electric brake output
Connection for two white power supply cables for the motor’s parking electric brake.
Activation is possible only when the bollard is completely lifted.
BAT
+
BAT Input for anti blackout electric brake feeder.
Permits the continuous power supply of the electric brake even without electrical energy, preventing the bollard
from lowering spontaneously in case of a blackout. Do not connect the batteries directly to this input but request
the original accessory STOPPY BAT.
SHIELD
ANT
ANTENNA
Antenna connection for the integrated receiver.
INSTALLATION MANUAL