Care and Maintenance
7-2
Pay attention to the mounting direction of the tube before
removal. An arrow on the tube PCB shows the optical
path. The spiral electrode points in direction of the flame
and can be seen through the lense. See also picture 2
Picture 2: Details of the tube-unit with view to the spiral
electrode
7.1.2
Mounting of the tube-unit
Insert the tube-unit into the holding trestle
Mount the PCB of the tube-unit with 2 plastic
screws
Put on the plug in the right direction (plug locks)
Screw on the plastic screw carefully to the holding
trestle. Pay attention not to destroy the UV-tube.
Insert the device into the housing and fix it with the
4 cross-head screws
Put on the purge air flange and fix it
Connect the CFC 100 and reset the operating
hour counter with the hand held terminal HT 100.
For more information take a look to BA HT100 EN.